This paper presents an experimental analysis of heat transfer using different shaped fills in a counter flow induced draft cooling tower. The main objective is to determine and compare the characteristics of the cooling tower using newly shaped (splash and film) fills and the regular used fills. The newly shaped fills are inverted U-shape cross-sectional splash fill and film fill with ripple plates. The obtained results show that the performance is affected by the type and arrangement of the fills. The modified splash fill has increased the wetted surface area of fill within the same volume compared to regular fills. The film fill with ripple plates has been used     such that water from the distribution device ran down on both surfaces of each ripple plate. By the arrangement of ripple plates, cooling loss by premature dropping off of water has been avoided. Performance factors like range, approach, effectiveness, cooling capacity, evaporation loss, percent loss are calculated from collected data for newly shaped fills, and regular shaped fills. It is observed that range, effectiveness, and cooling capacity increases with both newly shaped fills. When ripple plated film fill is used; range, effectiveness, and cooling capacity is found highest among the different shape of fills used in this study. At the same time evaporation loss and percent loss are found lowest for inverted-U shaped splash fill.

Fill Inverted U-shape ripple plate range effectiveness cooling capacity

Cited by 1

1 citation reported by external sources — individual citing-article records aren't available to list yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.