Skip to content
Research Article Open access CC BY 4.0

Development of a New Type-I Isotherm for Correction of Langmuir Isotherm’s Over-estimation of Adsorption at Higher Pressures

Adeolu J. Alawode, Olugbenga A. Falode

Physical Science International Journal · pp. 1–26 · Published 17 Oct 2019

10.9734/psij/2019/v23i330157

Abstract

Different gas equilibrium adsorption models (or isotherms) with various theoretical frameworks have been applied to quantify adsorbed volume (V) of gas (or fluid) through pressure-volume behaviour at a constant temperature. Most often, Langmuir isotherm (representing Type I Isotherm) has been used in modelling monolayer adsorption even though it yields over-estimation at higher pressures thus contradicting the description of Type I isotherm. Here, higher pressures refer to pressures above the adsorption saturation pressure(Ps) . Hence, in this work, a new Type I adsorption isotherm involving pressure(P), adsorption saturation pressure(Ps) , maximum adsorbed volume  and adsorbate-adsorbent resistance parameter  was developed using kinetic approach. The developed adsorption isotherm is V=  and it shows that Vmax is attained when pressure increases to Ps , above which no further gas adsorption occurs. The developed isotherm can be used to model all cases of monolayer adsorptions of gases (or fluids) on adsorbents. The developed and Langmuir isotherms were used in modelling secondary low-pressure gas adsorption data of different adsorbents and the qualities of fit were statistically assessed. For laboratory methane adsorption on Turkey’s shale sample at 25°C, the developed isotherm yields a correlation with an R2 value of 0.997 and predicts a maximum adsorption volume of 0.0450 mmol g-1 at a Ps  of 2,005 psia. However, Langmuir isotherm yields a correlation with an R2 value of 0.989 and predicts a maximum adsorption volume (Langmuir volume,VL ) of 0.0548 mmol g-1 at infinite Ps. At the higher-pressure range, the developed isotherm reveals that Langmuir isotherm is not a Type I isotherm but a "pseudo-Type I” isotherm.

Type I isotherm adsorption saturation pressure Langmuir isotherm monolayer adsorption.

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.