Skip to content
Research Article Open access CC BY 4.0

Identification of Groundwater Bearing Zones Using Geoelectrical and Electromagnetic Techniques at Tourah Area, South of Cairo - Egypt

Fardous M. Zarif

Journal of Geography, Environment and Earth Science International · pp. 1–16 · Published 26 Sep 2022

10.9734/jgeesi/2022/v26i930369

Abstract

The complex geology of Tourah area, south Cairo is a serious challenge for groundwater exploration, where the risk of unsuccessful groundwater drilling excavation for industrial purposes is well dressed, raising the need for better geophysical subsurface detection and characterization approaches in terms of water bearing and aquitard zones. Datasets from the study area were acquired using integrated geophysical techniques comprising of one Dimensional Vertical Electrical Soundings (1D VES) and one Dimensional Transient Electromagnetic (1D TEM) as well as two-Dimensional Electrical Imaging (2D ERI) which was restricted to the available spreading space as well as subsurface infrastructure noise. The results of 1D VES and 1D TEM soundings detected three to five geoelectric layers used to generate geoelectrical cross sections and maps of resistivity, thickness, and depth to water bearing zone. Moreover, the 2D ERI inversion profiles were able to image the first three layers and the depth of the water bearing zone [A] with significantly greater resolution due to their higher lateral and vertical resolutions compared to the traditional 1D VES and TEM interpolated cross section. The integration of the three geophysical methods displayed a smooth distribution of both marly limestone and fractured shaly limestone and claystone bands water bearing zones [A and B].  Resistivity values of the water bearing zone [A] ranges from 0.1 to 24 Ω m, with average thickness of 4 to 12 m, and depth to water of 1.5 to 13.6 m. In addition, [zone B] is the main water bearing zone of fractured shaly limestone and claystone bands (2 to 14 Ω m) which is detected at deep depth of 40 and 75 m. Two normal fault systems inferred from 1D interpretation are considered responsible for local recharging of the main Eocene aquifer over the study area. In conclusion, the outlined water bearing thickness as well as limited sources of groundwater recharge indicate that these water bearing zones may not provide a sustainable supply for the industrial development purposes in the future.

Groundwater electrical resistivity electromagnetic Eocene limestone industrial development

Cited by 2

2 citations reported by external sources — individual citing-article records aren't available to list yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.