Is the ‘Visual Fields Easy’ Application a Useful Tool to Identify Visual Field Defects in Patients Who Have Suffered a Stroke?
Jamie Spofforth, Charlotte Codina, Anne Bjerre
Ophthalmology Research: An International Journal · pp. 1–10 · Published 30 Jun 2017
10.9734/OR/2017/34947Abstract
Aims: To determine the level of agreement between the visual Fields easy application (VFE) for iPad and a standard clinical test for assessing peripheral vision in stroke survivors. Study Design: This was a prospective cross-sectional study comparing the VFE application to the Humphrey Field Analyser (HFA) SITA Fast c30-2 program in identifying and diagnosing visual field defects post-stroke. Place and Duration of Study: The ophthalmic department at Imperial College Healthcare NHS Trust. Data collection was undertaken between January 2016 and August 2016. Methodology: A total of 50 participants with a diagnosis of stroke and a suspected visual problem were recruited to the study. Normative data was collected from 50 participants with no history of stroke or visual loss. Analysis comprised of comparing the extent of the visual field loss detected by both the VFE and HFA, and clinically assessing the results for normality. Results: Bland-Altman analysis demonstrated that with more severe visual field loss, the agreement between both modalities was found to decrease. There was a higher proportion of false negatives with the VFE compared to the HVF. The bias towards detecting more missed test locations with the VFE application compared to the HFA was 6% for the normal participants and 2% for the stroke participants. The limits of agreement between the two modalities were large; 20% and 40% for the normal and stroke participants respectively. The sensitivity of the VFE application to determine an abnormal visual field in comparison to HFA was 88% and specificity was 76% in the stroke cohort based upon a clinical impression of its findings. The majority of stroke participants (88%) found the VFE test more comfortable to perform. Conclusion: As a screening tool, the VFE application is quick and easy to administer, preferred by patients and has good sensitivity and specificity for detecting the presence of an abnormal visual field when compared to HFA. In patients with extensive visual field loss, the VFE may overestimate visual field reduction.
Cited by 6
Supharat Jariyakosol, Patcharaporn Jaru-ampornpan, Anita Manassakorn · Eye and Brain · 2021
Ken Kitayama, Andrew G. Young, Alejandro Ochoa · Journal of Glaucoma · 2021
Chamini Wijesundera, Algis J. Vingrys, Tissa Wijeratne · Frontiers in Neurology · 2020
Parul Ichhpujani, Sahil Thakur, Roopjit K Sahi · Indian Journal of Ophthalmology · 2021
Jesús Vera, Alan N. Glazier, Mark T. Dunbar · Vision · 2025
Michael Christian Leitner, Stefan Hawelka · Neurocase · 2021
Related research
- The Relationship between Upper Extremity Motor Function and Oral Hygiene among Stroke Survivors: Study Protocol for a Mixed-Method Design — shares topic coverage
- Cognitive Recovery Outcome in a 12 Month Quasi-experimental Study Involving Sub-acute Stroke Survivors in Selected Hospitals in Nnewi, Anambra State, Nigeria — shares topic coverage
- Stroke Awareness and Drug Adherence among Adult Hypertensives in a Tertiary Health Care Centre — shares topic coverage
- The Impact of Upper Limb Functioning on Gait Patterns in Individuals with Post-Stroke Hemiplegia — shares topic coverage
- Circadian Variation of Stroke in a Tertiary Level Hospital — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
6
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.