Enhancing AC Electrothermal Micropumping by Integrating Temperature Bias and Surface Modification
Journal of Scientific Research and Reports · pp. 1465–1474 · Published 21 Apr 2014
10.9734/JSRR/2014/8876Abstract
This paper describes an experimental study of the improvement of bi-directional AC (Alternating Current) electrothermal micropump velocity by a surface modification process and the addition of a temperature bias. The work focuses on exploiting external temperature bias to enhance micropumping by AC electrothermal (ACET) effect. Adding temperature bias to a symmetrical electrode setup provides an advantage of bi-directional characteristic. Here an integrated AC micropump design is proposed, which is expected to solve the problem of on-chip pumping for biofluids. A polymer base nanocomposite coating consisting of a homogeneous mixture of silicon nanoparticles in polydimithylsiloxane (PDMS) is used to improve the hydrophobicity of the micropump surfaces. Due to the hydrophobic nature of PDMS and the monolayer coating with nanoscale surface roughness, the hydrophilic surface of temperature biased ACET micropump will transform to a hydrophobic surface. In addition to hydrophobicity improvement, adding a thin nanocomposite monolayer will physically separate the electrodes from the pumping liquid, thus eliminating their reaction, which is usually observed due to the application of voltage. In addition, the surface modification of micropump will decrease the friction loss and improve the pumping velocity. All experiments were done at 100 kHz VAC that also suppress the bubble generation. As a result, we could apply 7.5 Vrms (equivalent to 21.2 V, peak to peak) voltages to the symmetrical electrode arrays and higher pumping rates (2100 microns/sec) are achieved.
Cited by 1
Vishaka B Wasnik · 2016
Related research
- Synthesis and Structural Elucidation of 1, 4 Dihydropyrimido [1, 2-a] Benzimidazole — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.