This study applies an integrated aeromagnetic interpretation workflow to a contiguous dataset spanning the Precambrian Basement Complex of southwestern Nigeria and the adjacent south–south sedimentary province at the Niger Delta transition zone (6°00′–7°30′N; 5°00′–7°00′E). High-resolution airborne magnetic data acquired by NGSA/Fugro (2003–2009; 500 m line spacing; ~80 m terrain clearance; ~8 m along-track sampling) were corrected for diurnal variations and IGRF, gridded at 250 m, and processed using regional–residual separation, reduction-to-equator, first/second vertical derivatives, analytic signal, tilt derivative, and total horizontal gradient. Quantitatively, total magnetic intensity anomalies show a pronounced basement-to-basin transition, with values of ~70–119 nT over the northern crystalline domain and ~−10 to −58 nT over the southern sedimentary domain, defining a ~130 nT decrease over ~100 km. Residual anomalies range from approximately +66 nT to −104 nT, sharpening faulted basement blocks and contact relationships. Depth-to-source estimation using spectral analysis resolved shallow source depths of ~0.50-1.59 km and deeper source (basement/centroid) depths of ~2.99-8.27 km, with maximum deepening toward the basinward sector. Two-dimensional forward magnetic modelling (GM-SYS) across four profiles confirms fault-bounded basement relief, with basement depths varying from <1 km to >4 km and local vertical displacements exceeding ~2 km. Thermal modelling from spectral-derived Curie point depth indicates CPD values of ~6.10-18.05 km, corresponding to geothermal gradients of ~32.28-95.34 °C/km and estimated heat flow of ~80.69-238.36 mW/m². Spatially, high heat flow and high geothermal gradients coincide with shallow CPD zones, implying structurally influenced thermal anomalies across the basement–basin transition. The results demonstrate that inherited NE-SW and NW-SE structural fabrics persist across the province boundary and jointly control basement architecture and thermal variability, with implications for regional tectonic reconstruction and geothermal prospect screening.

Nigerian basement complex basement-basin transition euler deconvolution curie point depth geothermal gradient structural lineaments fault mapping GM-SYS forward modeling

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.