Skip to content
Research Article Open access CC BY 4.0

Comparative in vitro Analysis of Microbial Load Reduction on Dental Burs and Endodontic Files Following Different Decontamination Methods

N. Thasleema, Ektah Khosla, K. Korath Abraham, Ananthu Raj

International Journal of Research and Reports in Dentistry · pp. 238–245 · Published 10 Apr 2026

10.9734/ijrrd/2026/v9i1295

Abstract

Background: Dental instruments when reused poses significant risks of cross-infection. Autoclaving is the gold standard for sterilization, but repeated cycles can degrade the cutting efficiency of burs and files Aims: This study aims to evaluate the sterilization efficacy of a chemically enhanced glutaraldehyde solution using a 4-hour immersion protocol, compared to standard moist heat sterilization and 70% alcohol. Study Design: In vitro Comparative study Place and Duration of Study: Department of Pediatric and Preventive Dentistry, in collaboration with the Department of Microbiology, at Mar Baselios Dental College, between July 2025 and December 2025. Methodology: A total of 120 clinically contaminated instruments (diamond burs, hand K-files, and rotary NiTi files) were divided into four groups (n=30): Group A (70% Isopropyl Alcohol), Group B (4-hr Glutaraldehyde solution), Group C (Autoclave) and Group D (Control). Post-treatment, samples were incubated in Brain Heart Infusion Broth and plated on Brain Heart Infusion (BHI) agar to quantify Colony Forming Units (CFU/mL) Results: Both the Autoclave and 4-hour glutaraldehyde solution groups achieved complete elimination of viable microorganisms. Statistical analysis via ANOVA and Tukey's post-hoc test revealed no significant difference in efficacy between the two methods (P >.05). Conversely, 70% alcohol demonstrated significantly inferior performance, leaving residual contamination on all instrument types (P < .001). Conclusion: The 4-hour glutaraldehyde protocol is an ideal decontamination method, demonstrating microbial reduction levels comparable to the efficacy achieved by autoclaving. This offers a time-efficient and non-corrosive alternative for maintaining the longevity of heat-sensitive dental instruments.

Sterilization glutaraldehyde autoclave dental burs endodontic files microbial load infection control

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.