Prediction of Radiotherapy Dose Distribution for Glioblastoma Using Convolutional Neural Network Model
Ni Made Dian Rani, Ni Nyoman Ratini, Anak Agung Ngurah Gunawan, Gusti Ngurah Sutapa, Hery Suyanto, I Gde Antha Kasmawan
Asian Journal of Medicine and Health · pp. 1–8 · Published 5 Mar 2025
10.9734/ajmah/2025/v23i41198Abstract
Aims: This study aims to predict radiotherapy dose distribution for glioblastoma patients using Machine Learning with a Convolutional Neural Network (CNN) model. Study Design: This research used an experimental design with a quantitative approach to predict radiotherapy dose distribution for glioblastoma patients using a CNN model. The study involved training and testing the CNN model on medical imaging data from The Cancer Imaging Archive (TCIA), evaluating its performance based on Mean Squared Error (MSE), Root Mean Squared Error (RMSE), Structural Similarity Index Measure (SSIM), Dice Similarity Coefficient (DSC), Peak Signal to Noise Ratio (PSNR), Normalized Cross-Correlation (NCC). The results were analyzed to determine the model’s accuracy in replicating actual dose distributions, providing a data-driven assessment of its predictive capability. Place and Duration of Study: This research was conducted in the Department of Physics at Udayana University from October 2024 to January 2025. Methodology: The research involved 180 patient datasets divided into 126 training data and 54 testing data. The CNN architecture is implemented using the Google Collaboratory platform. Model evaluation is performed using MSE, RMSE, and SSIM to measure the accuracy of dose distribution prediction. Results: The MSE, RMSE, SSIM, DSC, PSNR, and NCC values obtained from the CNN model are 0.00015795, 0.01256, 0.979718, 0.9711, 32dB, and 0.96289 respectively. The low MSE and RMSE values indicate minimal prediction error, while the high SSIM confirms strong structural similarity between the predicted and actual dose maps. The DSC demonstrates excellent spatial overlap, and the high PSNR reflects high-quality dose reconstruction. Additionally, the NCC highlights strong correlation with the ground truth. Visually, the axial, coronal, and sagittal slices closely resemble the actual dose distributions, further validating the model’s accuracy. Conclusion: The CNN model demonstrates effectiveness in predicting the dose distribution for glioblastoma radiotherapy, achieving highly accurate evaluation metrics. Visually, the model exhibit patterns highly similar to the actual dose map.
Cited by 0
No indexed citations yet.
Related research
- Detecting Dental Caries through Captured Images Using the Machine Learning Technology Teachable Machine — shares topic coverage
- A Systematic Literature Review of Machine Learning Methods in Healthcare — shares topic coverage
- Diagnostic Accuracy of Artificial Intelligence for Breast Cancer Detection: A Systematic Review — shares topic coverage
- Artificial Intelligence in the Analysis of the Fetal Genome in Utero: A Critical Review of Current Paradigms, Clinical Utility and Future Horizons — shares topic coverage
- Advancing Glioblastoma Treatment: Challenges and Opportunities of Immune Checkpoint Inhibition — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.