A New Method for Calculating Residual Astigmatism Produced by Toric Intraocular Lens Rotation
Ophthalmology Research: An International Journal · pp. 368–377 · Published 15 Jul 2014
10.9734/OR/2014/12067Abstract
Aims: To report a new method for calculating residual astigmatism when exact and inexact cylinder power toric intraocular lenses (IOLs) are rotated. Methodology: Using Excel spreadsheets and sin2θ values, we expressed the cylinder powers of toric IOLs in percentage terms compared to corneal astigmatic powers and calculated values for various corneal astigmatisms and toric IOLs. From these values, we created charts of residual astigmatic powers and axes demonstrating the results of IOLs ranging from 50% to 150% and rotated 0º to 30º. Results: Comparing residual astigmatic powers, the rank orders for each IOL were as follows: 100%<90%<80% at 5º of rotation, 90%<100%<80% at 10º of rotation, and 90%<80%<75%<100% at 15º of rotation. Thus, lower cylinder power IOLs perform better than higher power IOLs when rotated over 5º. Furthermore, the residual astigmatic powers of 125% IOLs were always higher than those of 100% IOLs; however, the residual astigmatic powers of 75% IOLs became lower than those of 100% IOLs when rotation exceeded 15º. Conclusion: Our method shows that lower cylinder power IOLs are advantageous in environments where IOL rotation is likely and when inexact IOLs are utilized.
Cited by 2
Samir I Sayegh · 2020
Yinjie Jiang, Xun Chen, Mingrui Cheng · Translational Vision Science & Technology · 2025
Related research
- Ametropiain Children: A Review of 432 Cases — shares topic coverage
- Prevalence of Visual Impairment among Deaf and Mute Schools Children — shares topic coverage
- Pattern of Preoperative Astigmatism in Patients in South East Nigeria as Determined by Biometry — shares topic coverage
- Accuracy of Toric Intraocular Lens Axis Alignment Using Manual Slit Lamp Method and CALLISTO Eye Image-Guided System — shares topic coverage
- Correction of Pre-Existing Astigmatism with Phacoemulsification Using Spherical Intraocular Lens and Wave front Guided Surface Ablation: A Retrospective Case Series — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.