Skip to content
Research Article Open access CC BY 4.0

Flexural Behaviour and Environmental Impact of African Fan Palm Reinforced Concrete Beams under Symmetrical Loading Conditions

Edward C. Mansal, Charles K. Kankam, Evans Biney, Vincent Akortia, Alidu Babamu

Journal of Scientific Research and Reports · pp. 553–572 · Published 7 Oct 2024

10.9734/jsrr/2024/v30i102482

Abstract

The paper presents the results of investigation on reinforced beams adopting eco-friendly materials for sustainable concrete. The use of African fan palm is explored to mitigate the environmental impact aimed at reducing carbon emissions associated with the production and use of steel reinforcement.  The beams were tested under a four -point loading system with the ends simply supported. The test comprised twenty-three beams that were reinforced with African fan palm bars whilst two beams were reinforced with mild steel bars to serve as control beams. The study investigated the flexural strength and deformation characteristics of the beams under monotonic loading.  Two concrete strengths of 15.34N/mm2 or 22.37N/mm2 were adopted and proposed optimal tensile ratios for an under reinforced fan palm section. The parameters considered included the tension bars ratio (ρ), concrete compressive strength, span-to-effective-depth ratio and loading conditions. A linear elastic behaviour of both fan palm and steel reinforced concrete beams was observed to the point of first crack load beyond which the beam stiffness continued to reduce until failure.  A comparison of the experimental results with results of theoretical analysis of the beams revealed that a 1.22% increase in the tensile ratio of steel in the control beams increased the cracking moment (Mcr) to 36%, while the fan palm beam of the same size and same concrete strength with a higher tensile ratio of 9.69% exhibited a lower Mcr of 11.86%. This shows a significant effect of reinforcing steel bars on concrete cracking compared to the fan palm. The averages of experimental to theoretical failure loads of fan palm to steel were compared with failure loads of 36.52kN to 20.19kN and 32kN to 19.78kN respectively. These results of the study based on the failure mode, and failure loads, highlights the suitability of using African fan palm as substitute reinforcing material for low rise buildings. Furthermore, the study also proposed minimum and maximum tensile ratio of 0.76% and 5.60% respectively for fan palm reinforced concrete beams based on the Indian Standard and modulus of elasticity of steel.

Fan palm reinforced beams tensile ratio modulus of elasticity cracking load failure load

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.