Dielectric Blood Coagulometry as a Novel Coagulation Test

Sahoko Chiba, Ken Uchibori, Takasato Fujiwara, Tomoyuki Ogata, Shuta Yamauchi, Tuyoshi Shirai, Masahiro Masuo, Tsukasa Okamoto, Tomoya Tateishi, Haruhiko Furusawa, Toshihide Fujie, Hiroyuki Sakashita, Kimitake Tsuchiya, Meiyo Tamaoka, Yasunari Miyazaki, Naohiko Inase, Yuki Sumi

Journal of Scientific Research and Reports · pp. 180–188 · Published 10 Oct 2014

10.9734/JSRR/2015/10674

Abstract

Background: Dielectric blood coagulometry (DBCM) has been presented as a new test for estimating the risk of venous thromboembolism (VTE) by measuring the permittivity change associated with blood coagulation. Yet no earlier studies have investigated the clinical utility of DBCM. Objective: We aimed to estimate the clinical utilities of DBCM. Methods: Our group prospectively measured DCT, the clotting time estimated by DBCM, in 192 inpatients at the Department of Respiratory Medicine of Tokyo Medical and Dental University Hospital between May 2011 and January 2013. We also measured in 28 healthy volunteers as control group. Additionally, other laboratory findings were evaluated for both patients and controls. Results: The normal range of DCT was estimated at between 21.0 and 54.8 minutes based on measurements of healthy volunteer controls. Coagulation was significantly accelerated in patients with interstitial pneumonitis, lung cancer, chronic obstructive pulmonary diseases and sleep apnea syndrome, when measured by DBCM. There was little correlation between DCT and conventional coagulation test results. Conclusion: DBCM is a novel tool for estimating blood coagulation and may be useful for identifying patients at high risk of thrombosis. However a single DCT measurement would be insufficient for a definite diagnosis of thrombosis. Further long-term observation is needed to evaluate the usefulness of DBCM.

DBCM (Dielectric Blood Coagulometry) DCT (clotting time estimated with dielectric blood coagulometry) thrombosis clotting time pulmonary thromboembolism venous thromboembolism

Cited by 10

Incubation-free Wash-free Tissue Factor-based Functionalization of Gold Electrodes for Dielectric Blood Coagulometry

Hanif Alizadeh, Calvin Abonga, Christopher A. Delianides · 2025 IEEE BioSensors Conference (BioSensors) · 2025

Monitoring time course of human whole blood coagulation using a microfluidic dielectric sensor with a 3D capacitive structure

Debnath Maji, Michael A. Suster, Evi Stavrou · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · 2015

ClotChip: A Microfluidic Dielectric Sensor for Point-of-Care Assessment of Hemostasis

Debnath Maji, Michael A. Suster, Erdem Kucukal · IEEE Transactions on Biomedical Circuits and Systems · 2017

Principles of Dielectric Blood Coagulometry as a Comprehensive Coagulation Test

Yoshihito Hayashi, Marc-Aurèle Brun, Kenzo Machida · Analytical Chemistry · 2015

Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry

Yoshihito Hayashi, Marc-Aurèle Brun, Kenzo Machida · Biorheology · 2017

A PMMA microfluidic dielectric sensor for blood coagulation monitoring at the point-of-care

Debnath Maji, Michael A. Suster, Erdem Kucukal · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · 2016

Assessment of whole blood coagulation with a microfluidic dielectric sensor

D. Maji, M. De La Fuente, E. Kucukal · Journal of Thrombosis and Haemostasis · 2018

Simultaneous multiparameter whole blood hemostasis assessment using a carbon nanotube-paper composite capacitance sensor

Praveen K. Sekar, Xin M. Liang, Seong-Joong Kahng · Biosensors and Bioelectronics · 2022

A Portable Palmtop Dielectric Blood Coagulometer with a Single-Chip Multichannel Microfluidic Sensor

Christopher A. Delianides, Hanif Alizadeh, Calvin Abonga · 2025 IEEE BioSensors Conference (BioSensors) · 2025

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

10

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.