Validating Response of AC Microgrid to Line-to-Line Short Circuit in Islanded Mode Using Dynamic Analysis
Archives of Current Research International · pp. 1–15 · Published 31 Aug 2019
10.9734/acri/2019/v18i330135Abstract
This paper is presented in an attempt to validate the dynamic response of a microgrid to line-to-line short circuit. The microgrid components include two identical Wind Turbine Generators (WTGs) tied to a 100MVA, 13.8kV utility via a Point of Common Coupling (PCC). The utility-microgrid testbed is modeled in SIMPOWERSystems® using two Doubly-Fed Induction Generators (DFIGs) in the microgrid side. While in islanded operating mode, line-to-line short circuit fault is applied at 6.0s and withdrawn at 8.0s, obtaining a 50.0s dynamic response of the system for different fault locations, under voltage and reactive power control regimes of the wind turbine controller. For measurement purpose, the absolute value of the stator complex voltage is transformed to reference frame. Bidirectional power flow between the two feeders is established in the study. The study also confirms that the microgrid composed of DFIGs offer reactive power management capability, particularly by presenting superior performance when stressed under Q control regime than under V control regime. Finally, the response of the testbed to line-to-line short circuit has been validated and shown to be consistent with established short circuit theory.
Cited by 0
No indexed citations yet.
Related research
- Dynamics of Spermatogenesis — shares topic coverage
- Spatio-temporal Analysis of the Impact of Rainfall Dynamics on the Water Resources of the N'zi Watershed in Côte d'Ivoire — shares topic coverage
- Estimating the Money Demand Function and a Demystification of the Endogeneity-Exogeneity Nexus of Money Supply: The Case of Zimbabwe (1991-2008) — shares topic coverage
- Review of Microgrids and Associated Protective Systems — shares topic coverage
- A Review of Control Strategies for Microgrids — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.