Skip to content
Research Article Open access CC BY 4.0

Interference with Creatinine Assay by IgM-λ Monoclonal Protein in Lithium Heparin Blood Collection Tube from a Malignant Lymphoma Patient

Nobuyasu Yukimasa, Wataru Oboshi, Keisuke Hayashi, Hiroko Kuribayashi, Ryuichi Uzawa, Kunihiko Fukuchi, Takehiro Nakamura

International Journal of Medical and Pharmaceutical Case Reports · pp. 1–7 · Published 6 Oct 2016

10.9734/IJMPCR/2016/29258

Abstract

Aims: Analytical interference in the clinical laboratory is a well-known phenomenon. When analyzing samples containing monoclonal immunoglobulins (M proteins), various problems could be encountered in the clinical laboratory data. Presentation of Case: The authors report a patient with false elevated plasma creatinine concentration due to interference of monoclonal IgM in a routine test for creatinine determination. In the present case the interference might be caused by M protein precipitation, due to an increased turbidity and an apparent increase of absorbance in the clinical chemistry creatinine assay. Sia water test can provide a first clue to M protein aggregation; confirmation can be obtained by observing the time/absorbance curves of the analysis. When a Sia water test was performed with changes in the salt concentration, protein aggregation occurred at a higher salt concentration for the lithium (Li)-heparin plasma sample than the serum. Discussion and Conclusion: These results suggested that the M protein of this patient, when interacted with Li-heparin, is more readily insolubilized. Subsequently, a reaction reproduction experiment was performed by adding the M protein component roughly purified to Li-heparin blood collection tubes. These results might support the aggregation of the M protein of this patient in the reaction solution due to its interaction with Li-heparin.

Creatinine measurement lithium (Li)-heparin plasma monoclonal immunoglobulin (M protein) Sia water test.

Cited by 1

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.