Evaluation of the Influence on the Use of Additional Filtration in Pelvic Radiographic Examinations Using a Phantom Object
V. T. Claus, A. P. Soares Flávio
Advances in Research · pp. 247–259 · Published 14 Aug 2023
10.9734/air/2023/v24i5975Abstract
Aims: This study aimed to determine the effect of additional filtration on the image quality and dose reduction in pelvic radiographic examinations. Study Design: Mention the design of the study here. Place and Duration of Study: The research was conducted at a municipal emergency service radiology department in Rio Grande do Sul, Brazil. Methodology: Using a simulator object to replicate clinical examination conditions. The radiographic equipment was fitted with aluminum, copper, and copper-aluminum composition filters to identify the optimal filtration for reducing radiation doses and maintaining image quality. Results: Results showed that filtration effectively reduced dose and average absorbed dose in internal organs, with the greatest reduction observed with the copper filter. However, excessive filtration resulted in a decrease in image quality, particularly with the copper filter. The Figure of Merit (FOM) demonstrated that keeping the electrical factors of the X-ray tube consistent (70 kVp and 32 mAs) and using an additional 2.5 mmAl filter could optimize pelvic radiographic examinations, based on the diagnostic IQ criteria established by the service. Conclusion: In conclusion, the FOM revealed that using additional filtration of 2.5 mmAl and maintaining the X-ray tube's electrical factors at 70 kVp and 32 mAs could reduce the KERMA in air by 49.8% in the patient, 41.5% in the testes, 35.5% in the bladder, 30.4% in the ovaries, 29.7% in the bone marrow, and 35.3% in the total effective dose of the examination, while maintaining equivalent image quality.
Cited by 0
No indexed citations yet.
Related research
- Analysis of Acceptance of Radiation Doses for Radiation Workers in the Radiology Facility of Bali Mandara Hospital — shares topic coverage
- Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Chest CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
- Abdominal CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.