Hemodialysis-associated Oxidative Stress: Comparison of Helixone® and Polysulfone® Dialyzer
Mourad Errasfa, Fatima Zahra Batta, Kaoutar Alaoui Sekkouri, Chakib Maaroufi, Mohamed Arrayhani, Tarik Sqalli Houssaini
Journal of Advances in Medical and Pharmaceutical Sciences · pp. 1–7 · Published 3 Mar 2016
10.9734/JAMPS/2016/24141Abstract
Background: Patients at end stage renal failure require hemodialysis, a process that contributes to oxidative stress, where the quality of hemodialysis membrane plays a key role. Aim of the Study: We sought to investigate the effect of two different hemodialysis membranes (Helixone® vs Polysulfone®) on several blood biologic and oxidative stress parameters. Patients and Methods: Among 86 patients of our hemodialysis facility at the University Hospital, 12 patients were included in the study according to inclusion and exclusion criteria. Patients used Polysulfone® membrane in a first step of the study, then they switched to Helixone® membrane. Under the two kinds of membranes, we measured routine biologic parameters, and pre- and post- dialysis plasma oxidative stress parameters (malondialdehyde and Total Anti-Oxidant Activity, as assessed respectively, by the method of thiobarbituric acid, and an anti-oxidant activity commercial kit). Results: With both Polysulfone® and Helixone® dialyzers, there was an important and significant increase of malondialdehyde upon a single hemodialysis session, however, the increase of malondialdehyde concentration was significantly reduced with Helixone® dialyzer as compared to Polysulfone® one. Plasma total anti-oxidant activity was reduced significantly upon a single hemodialysis session with both dialyzers, however, such a reduction was significantly higher with Polysulfone® (28% reduction) than with Helixone® (11.7% reduction) dialyzer. The levels of other routine blood parameters related to the performance of dialysis process (urea, uric acid, creatinine) under both dialyzers were similar. Conclusion: Hemodialysis-associated oxidative stress, as assessed by MDA concentration and plasma total anti-oxidant activity, seems to be significantly reduced with Helixone® dialyzer when compared to Polysulfone® dialyzer. This difference may bring positive impact on hemodialysis-associated side effects on cardiovascular and cerebrovascular systems.
Cited by 0
No indexed citations yet.
Related research
- Effect of Zinc Supplementation on Blood Pressure and Complete Blood Count in Hemodialysis Patients — shares topic coverage
- Impact of Infection Prevention and Control Education Program on Improving Knowledge, Attitude and Practices of the Healthcare Staff in Hemodialysis Unit at Egyptian Tertiary Care Facility — shares topic coverage
- Exceptional Fertility and Poor Fetal Outcome in a Female with 17-Year Hemodialysis: A Case Study and Mini-review — shares topic coverage
- Effects of Changing Anticoagulation with Unfractionated Heparin into Enoxaparin in Hemodialysis Patients:Prospective Non Randomized Unicentre Study — shares topic coverage
- Two Endogenous Endophthalmitis Cases Accompanying Nephrological Condition in Diabetic Patients — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.