Harmonic Scalpel Versus Bipolar Diathermy in Trans -areolar Thyroidectomy
M. S. Abdelhamid, H. A. Nafady, A. Z. Garib, A. M. Rashad, S. S. Soliman, T. M. EL – Gaabary
Asian Journal of Research in Surgery · pp. 31–35 · Published 19 Oct 2018
Abstract
Background: Years ago the LigaSure device and Harmonic scalpel were tried in thyroid surgery. It was found to be superior to hand-tying techniques. The aim was to assess bipolar diathermy against harmonic scalpel regarding operation time, cost and complications. Videoscopic neck surgery is developing despite the fact that only potential spaces exist in the neck. These approaches are more appealing since the size of the incision of the conventional approach seems to be out of proportion compared to the small size of the tumours. Purpose: to assess the applicability of bipolar diathermy in transareolar thyroidectomy. Patients and Methods: The interventions were led at Beni-suef University Hospital between January 2017 and December 2017, after the patients fitted both the inclusions and exclusions criteria. This study enrolled 30 co-operative patients aged 18-60 years with unilateral thyroid lobe nodule, nodules or diffused swelling with the largest diameter less than 4 cm. A total of 30 patients went with the transareolar thyroid lobectomy, 20 went with the harmonic scalpel and 10 with the bipolar diathermy. Thyroid nodules were less than 4-cm in their largest transverse diameter. Thyroid gland volume was less than 20-ml as estimated by US. Cranio-caudal axis of the lobes must not exceed 7-cm. Results: Mean operating time was 90 min (57 -135) with the harmonic scalpel while it was 105 min (70-145) minutes. No significant post-operative bleeding was seen in both groups. LOS was same in both groups. Marked reduction in the cost was reported. Conclusion: Transareolar thyroidectomy with bipolar diathermy is associated with a marked reduction in cost compared to transareolar thyroidectomy with harmonic and this worth the long operating time.
Cited by 0
No indexed citations yet.
Related research
- Isolation, Molecular Detection and Antimicrobial Sensitivity Profile of Pasteurella multocida Isolates from Cattle Affected with Haemorrhagic Septicaemia in the Puducherry Region — shares topic coverage
- Using Digital Relays for Improved Power Transformer Differential Protection — shares topic coverage
- Acute Effects of Ultrasonic Shears and Monopolar Electrosurgery on Sciatic Nerve Electrophysiology — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.