Pseudotumors following adverse reactions to metal debris are most commonly associated with metal-on-metal (MoM) total hip replacements (THRs). However, their occurrence in non-metal-on-metal (non-MoM) THRs, such as metal-on-polyethylene (MoP), is rare. We present a case of pseudotumor formation secondary to catastrophic polyethylene liner wear in a MoP THR two decades after the index procedure. A 68-year-old male presented with progressive pain, stiffness, and swelling around the left hip 20 years after receiving a MoP total hip arthroplasty. Clinical evaluation revealed a firm, non-fluctuant periprosthetic mass. Radiographs demonstrated eccentric femoral head position with a large expansile osteolytic lesion. MRI revealed a heterogeneous soft tissue mass with metal artifact. Serum cobalt and chromium levels were elevated. Aspiration yielded sterile dark fluid, and histopathology showed lymphoplasmacytic infiltrates consistent with an ALVAL-type response. Intraoperatively, complete polyethylene liner wear was noted with metal-on-metal contact between the cobalt-chromium head and titanium shell, generating extensive metallosis and pseudotumor formation. The patient underwent a two-stage revision, including pseudotumor excision and distal femoral replacement. Pseudotumors can develop in non-MoM THRs due to catastrophic polyethylene wear and secondary metallosis. Long-term follow-up is essential for early detection of wear-related complications, even in conventionally inert bearing surfaces. Surgeons should maintain vigilance for late-onset masses in THA patients, regardless of implant type.
Cited by 0
No indexed citations yet.
Related research
- Exploring Hemophilic Pseudotumors: A Comprehensive Case Series — shares topic coverage
- Inflammatory Pseudotumor of Maxilla: Masquerading as Aggressive Malignancy — shares topic coverage
- Catastrophic Wear of Tibial Component of Total Knee Replacement Due to Neglected Dislocation of Polyethylene Insert: A Case Report — shares topic coverage
- Total Hip Arthroplasty Following Failed Internal Fixation of Hip Fractures: Clinical and Radiological Outcomes in a Retrospective Study of 14 Cases — shares topic coverage
- Acute Primary Total Hip Arthroplasty Combined with Open Reduction and Internal Fixation of the Posterior Acetabular Wall for Ipsilateral Femoral Neck Fracture Following a High-energy Fall: A Case Report — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.