Skip to content
Research Article Open access CC BY 4.0

Catastrophic Wear-induced Pseudotumor Formation 20 Years Post-total Hip Arthroplasty: A Rare Complication of Non-Metal-on-Metal (MoM) THR

Ifeanyi C. Agwulonu, Olusunmade Opeyemi, Hakeem Badmus, Idowu Oluwseyi, Osuala Chinonye, Obong Udemeobong, Moses O. Oyewumi

Asian Journal of Case Reports in Medicine and Health · pp. 300–308 · Published 6 Sep 2025

10.9734/ajcrmh/2025/v8i1258

Abstract

Pseudotumors following adverse reactions to metal debris are most commonly associated with metal-on-metal (MoM) total hip replacements (THRs). However, their occurrence in non-metal-on-metal (non-MoM) THRs, such as metal-on-polyethylene (MoP), is rare. We present a case of pseudotumor formation secondary to catastrophic polyethylene liner wear in a MoP THR two decades after the index procedure. A 68-year-old male presented with progressive pain, stiffness, and swelling around the left hip 20 years after receiving a MoP total hip arthroplasty. Clinical evaluation revealed a firm, non-fluctuant periprosthetic mass. Radiographs demonstrated eccentric femoral head position with a large expansile osteolytic lesion. MRI revealed a heterogeneous soft tissue mass with metal artifact. Serum cobalt and chromium levels were elevated. Aspiration yielded sterile dark fluid, and histopathology showed lymphoplasmacytic infiltrates consistent with an ALVAL-type response. Intraoperatively, complete polyethylene liner wear was noted with metal-on-metal contact between the cobalt-chromium head and titanium shell, generating extensive metallosis and pseudotumor formation. The patient underwent a two-stage revision, including pseudotumor excision and distal femoral replacement. Pseudotumors can develop in non-MoM THRs due to catastrophic polyethylene wear and secondary metallosis. Long-term follow-up is essential for early detection of wear-related complications, even in conventionally inert bearing surfaces. Surgeons should maintain vigilance for late-onset masses in THA patients, regardless of implant type.

Pseudotumor total hip arthroplasty polyethylene wear Adverse Local Tissue Reaction (ALTR) metallosis

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.