Comparison of Imaging Quality between 2D Synthesised Mammograms Reconstructed from Digital Breast Tomosynthesis and 2D Full-field Digital Mammograms
Johannes Peters, Gudrun Peters, Debra Ardath Meerkotter, Katie Daniels, Jonathan Shulman
Journal of Advances in Medicine and Medical Research · pp. 1–9 · Published 11 Nov 2016
10.9734/BJMMR/2016/29709Abstract
Objectives: The aim of this study was to evaluate if 2D synthesised mammograms reconstructed from a digital breast tomosynthesis 3D data set are noninferior in imaging quality when compared to 2D full field digital mammograms. Methods: A random sample of 100 mammograms was selected from a dedicated private breast imaging service in Australia. Selected cases were classified as normal, benign or malignant. Five breast radiologists retrospectively rated the overall imaging quality and lesion quality of 2D synthesised mammograms when compared with 2D full field digital mammograms. Cases with metal artefact were reassessed using metal artefact post processing software. Results: Overall image quality for all cases before metal reduction post processing was 0.39 (CI 0.32, 0.45) and after post processing 0.40 (CI 0.33, 0.46). Overall lesion quality for all cases before metal reduction post processing was 0.46 (CI 0.28, 0.65) and after post processing 0.58 (CI 0.43, 0.72). Results confirm noninferiority of both overall image quality and overall lesion quality when comparing 2D synthesised mammograms to 2D full field digital mammograms. Metal artefact reduction had an impact on improving ratings for 2D synthesised mammograms. Conclusions: 2D synthesised mammograms reconstructed from a digital breast tomosynthesis 3D data set are noninferior when compared to 2D full field digital mammograms. This results in reduction of radiation dose and time under compression. Advances in Knowledge: 2D synthesised mammograms reconstructed from a digital breast tomosynthesis 3D data set can replace 2D full field digital mammograms. Metal artefact reduction software should be used routinely.
Cited by 0
No indexed citations yet.
Related research
- Breast Cancer Knowledge and Mammography Uptake among Women Aged 40 Years and Above in Calabar Municipality, Nigeria — shares topic coverage
- A Case Report of Breast Myofibroblastoma: A Bad Looking Benign Tumor — shares topic coverage
- Reducing False Positives and False Negatives in Artificial Intelligence-assisted Imaging Screening: A Critical Review of Accuracy, Error Mechanisms and Clinical Translation — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.