Technical and Enviro-economic Analysis of a 0.78 kWp PV System
Wilkins K. Cheruiyot, Eliaz K. Komen, Joel K. Tonui, Richard A. Kinyamal
Journal of Energy Research and Reviews · pp. 1–12 · Published 10 May 2024
10.9734/jenrr/2024/v16i6353Abstract
Aim: To determine the technical, economic and environmental performance analysis of an installed PV backup system. Study Design: To attain this goal, analysis were performed using a freely available PVSyst 6.7.0 software tool. Economic evaluation was performed using respective present worth of individual component prices. Environmental performance comparison is made between the PV system and diesel generator when each is used as an independent backup system. Input in-situ measured data were determined, measured and keyed into the tool. Place and Duration of Study: The system is installed in an institutional building in a tropical climatic zone with coordinates 0.42 N and 35.03 E. The system was studied for a period of one year where data was collected and recorded for techno-enviroeconomic analysis. Methodology: The system consists of four PV modules rated at 0.78 KWp, charge controller and an inverter unit and battery bank, and is utilized as a power backup system to supply electricity whenever power failure occurs, which is frequent and real in Kenya. The techno-enviroeconomic performances analysis of the system were evaluated using the PVSyst software, a freely available design and analytical tool, where input data were measured and recorded at the site. Results: The performance analysis of the system showed that PV array efficiency of 13.24%, FF of 0.68, CF of 21.23%, and PR of 73.63% and generated electrical energy of 1092 kWh/year. The LCOE of PV electricity was 0.059 $/kWh, while total saving of CO2 emission in tons of CO2 was 9.0 tCO2 with LCE value of 331 gCO2/ kWh. Conclusion: Techno- enviroeconomic performance results of the studied PV system show that the system can contribute significantly to the mitigation of CO2 emission. This work also could be helpful for consumers and policy makers in the choice of renewable based or fossil based backup generation systems.
Cited by 0
No indexed citations yet.
Related research
- Performance Analysis of Dhaba Size Improved Biomass Cook Stove for Commercial Application as Clean and Efficient Cooking Solutions — shares topic coverage
- Conformity Assessment in Senegal: Conformity Tests in Laboratories as the Basis for Quality Infrastructure — shares topic coverage
- Design and Development of a Sustainable Shell and Tube Heat Exchanger for Use in a Higher Institution — shares topic coverage
- MMPP/G/m/m+r Queuing System Model to Analytically Evaluate Cloud Computing Center Performances — shares topic coverage
- Development of Computer Software for Design of 16+4 Speed Gearbox for Tractor and Practical Validation — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.