Effects of Damp-heat on Shunt, Series Resistances and Fill Factor into Crystalline Silicon Photovoltaic Solar Modules in Tropical Zone
Minadohona Maxime Capo-Chichi, Vianou Irénée Madogni, Clément Adéyèmi Kouchadé, Géraud Florentin Hounkpatin, Macaire Agbomahéna, Basile Kounouhewa
Physical Science International Journal · pp. 1–16 · Published 2 Nov 2022
10.9734/psij/2022/v26i6747Abstract
Most solar module manufacturers guarantee the minimum performance of their modules for 20 to 25 years. But some time after their installation, one observes faults which appear on the various components of these modules. During long-term exposure to severe climatic conditions, these faults, which accumulate over time, lead to performance losses of the module. This performance degradation is due to several factors such as humidity, temperature, heat, irradiation etc. These factors cause various degradation processes which can be electrical, chemical, mechanical, thermal, etc. The tropical zone, the middle of our study being characterized by high heat and humidity, has definite impacts on the electrical parameters of photovoltaic modules. The electrical parameters degradation is among others cause of photovoltaic modules performance loss. This study purpose is to study the degradation of the shunt resistance, the series resistance and the form factor of photovoltaic modules installed in tropical areas in order to appreciate their impact on the performance loss of the latter. For that, we used Peck performance degradation analytical model and Braisaz degradation analytical models of shunt resistance and the series resistance to calculate over a period of forty years, in real conditions in the tropical environment, the degradation of these electrical parameters of the photovoltaic module. The results obtained are compared to those obtained during the Hulkoff experimental tests in the state of Miami in Florida in 2009. The degradation rates obtained in the six cities concerned by the study vary between 17.33-35.67% for resistance shunt, between 3.77-7.55% for the series resistance and between 8-19% for the fill factor. In addition, these electrical parameters degradation rates obtained experimentally by Hulkoff and taken up by [1], are respectively 35.14% for the shunt resistor, 9.43% for the series resistor and 3.03% for the fill factor over the study period. So, future researches on crystalline silicon photovoltaic solar module can be effect of Damp-Heat on short circuit current and open circuit voltage in tropical area.
Cited by 3
Amandeep Singh Makhija, S. Bohra · Progress in Energy · 2023
Meriem Farou, Abdelhak Djellad, Sofiane Chiheb · Energy Reports · 2025
Saeed Iqbal, Syed Maaz Hasan, Y. Ayaz · IEEE Access · 2025
Related research
- Photochemical Study for Solar Energy Conversion & Storage in Solar Cell: Yellow 5GN-EDTA System — shares topic coverage
- Numerical Analysis of the Combined Effect of BSF Thickness and Doping on the Performance of an a-Si:H/c-Si SHJ Cells Cell — shares topic coverage
- Comparative Study on the Photovoltaic Properties of Dye-Sensitized Solar Cells (DSCs) Based on Different Counter Electrode Configurations — shares topic coverage
- Impact of External Electric Field on the Performance Parameters of PV Solar Cells under High Light Concentration — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
3
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.