Sensitivity and Specificity of Magnetic Resonance Spectroscopy (MRS) in the Diagnosis of Meningiomas
Asian Journal of Research and Reports in Neurology · pp. 194–205 · Published 12 Dec 2023
Abstract
Background: Meningiomas are the most common extra axial tumors of brain accounting 13-26% of primary intracranial neoplasm. They are the most common non glial tumor of central nervous system (CNS). Meningiomas arise from the arachnoid cells called meningothelial cell and appear as extra axial, sharply demarcated, solid mushroom imaging pattern with dense homogenous contrast enhancement on CT and MRI. Objective: To determine the sensitivity and specificity of Magnetic Resonance Spectroscopy (MRS) in the Diagnosis of Meningiomas. Methods and Materials: This cross-sectional study was conducted on 45 patients with suspected meningioma who were referred to the Radiology and Imaging Department of Bangabandhu Sheikh Mujib Medical University (BSMMU) from the Department of Neurology and Neurosurgery during period from October 2019 to September 2021. Magnetic Resonance Spectroscopy (MRS) findings were evaluated taking into account the histopathology as a gold standard. Statistical analyses were carried out by using SPSS version 23.0. The quantitative observations were indicated by frequencies. Receiver operating characteristic (ROC) curve was generated to determine the cutoff value for the best sensitivity, specificity, negative and positive predictive values of choline /N-acetyl aspartate ratio with regard to diagnosis and characterization of meningiomas. Results: In MRS out of 45 patients 36(80%) patients were diagnosed as meningioma among them 30(67%) patients had increased alanine, 38(84%) patients had increased choline, 22(49%) patients NAA had not detected, 20(44%) patients NAA were minimally detected. Remaining 9(20%) patients had non-meningioma. In histopathology out of 45 patients 38(84%) patients had meningioma and 7(16%) patients had non meningioma. Histopathology showed 27(71%) patients was grade I, 3(8%) was grade II and 8(21%) was grade III. Increased lactate was detected in 11 patients, out of which 9(82%) patients were found high grade and 2(18%) patients were low grade meningiomas. The validity of meningioma by MRS was represented by calculating sensitivity, specificity, accuracy, positive and negative predictive values taking into account histopathology as gold standard. Sensitivity was 89.47%, specificity was 71.43%, accuracy was 86.67%, PPV was 94.44% and NPV was 55.56%. Based on the receiver-operator characteristic (ROC) curve choline/N-acetyl aspartate ratio had area under curve 0.850. Receiver-operator characteristic (ROC) was constructed by using choline /N-acetyl aspartate ratio, which gave a cut off value ≥2.99, with 80.0% sensitivity and 62.5% specificity for prediction of high grade. Conclusion: The study suggested that MRS findings were consistent with low specificity in the diagnosis of meningiomas but MRS can characterize the types of meningiomas keeping histopathology as a gold standard. Increased alanine, decreased or absent NAA, increased choline, decreased creatine could be the spectroscopic parameters for the diagnosis of meningiomas and by using choline/N-acetyl aspartate ratio more sensitivity was found to predicted high grade along with lactate peak.
Cited by 0
No indexed citations yet.
Related research
- Analysis of TE Variations on SNR and CNR Values in Lumbar MRI T2WI Sequences at Bali Mandara Regional General Hospital — shares topic coverage
- Effect of Variation Number of Excitation (NEX) Parameter on the Quality Image of Magnetic Resonance Imaging Genu on T2 Weighted Image Sequence at Bali Mandara Regional General Hospital, Indonesia — shares topic coverage
- Retrospective Analysis of Incidental Duodenal Diverticulum: CT and MRI Findings — shares topic coverage
- A Case Report on Arnold Chiari Type III: Constellation of Disorders, from Diagnosis to Treatment — shares topic coverage
- Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) in Detecting Breast Tumors — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.