Comparative Analysis of Current-Voltage Characteristics of Photovoltaic (PV) Systems in Selected Climatic Regions in Cross River State, Nigeria
Emmanuel B. Ettah, Goodness N. Nwabueze, U. J. Ekah
Journal of Energy Research and Reviews · pp. 29–37 · Published 11 Apr 2024
10.9734/jenrr/2024/v16i4345Abstract
This study investigated the effect of solar radiation’s intensity and ambient temperature on the current-voltage (I-V) characteristics of monocrystalline and polycrystalline photovoltaic (PV) systems in the generation of electricity in Calabar and Okuku, Cross River State, Nigeria. Appropriate measuring devices were employed to record daily readings of these parameters at the study locations, from July to August 2022. The data were collected and results graphically analyzed and calculated. The results indicate that current (Isc), voltage (Voc) as well as the maximum power (Pmax) of both module types increased positively with increase in solar radiation and ambient temperature. Results from collected and computed data also show average daily readings across the locations for solar radiation ranging between 271Wm-2 and 409Wm-2 and ambient temperature between 320C and 370C. The calculated Pmax ranges between 49W and 63W from the 130W solar modules used for the investigation. Another notable result is that the polycrystalline module exhibits higher Pmax than the monocrystalline module in both locations. In spite of the low solar radiation and ambient temperature obtained during this study period, which is considered the worst climatic period of the year (July and August), it is desirable and recommendable to employ solar modules as an alternative power generation in Calabar and Okuku, Cross River State, Nigeria.
Cited by 0
No indexed citations yet.
Related research
- Optimal Spike Detection Technique Based on Amplitude Threshold — shares topic coverage
- Three Phase Inverting Using Pulse Width Modulation Controlled by 6802 Motorola Microprocessor — shares topic coverage
- Conformity Assessment in Senegal: Conformity Tests in Laboratories as the Basis for Quality Infrastructure — shares topic coverage
- Measuring the Voltage, Current and Resistance of the LDR Sensor through the Arduino UNO — shares topic coverage
- Overvoltages during Single-Phase Earth Fault in Neutral-Isolated Networks (10÷35) kV — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.