Skip to content
Research Article Open access CC BY 4.0

MRI Scan Early after Implantation of an MRI Conditional Implantable Cardioverter-Defibrillator: Case Report

S. Chitnis Nishad

Asian Journal of Cardiology Research · pp. 46–53 · Published 17 Jun 2019

Abstract

Introduction: MRI scans are not recommended for the first four weeks after device implantation. However, conditions like hypoxic-ischaemic encephalopathy can only be evaluated by MRI. A case where MRI brain was done in a patient with HIE four days after ICD implantation has been reported. Case History: A 54 year old male with old anterior wall myocardial infarction presented with recurrent monomorphic, pulseless ventricular tachycardia. Anti-arrhythmic treatment resulted in severe junctional bradycardia for which temporary pacemaker was inserted. After 48 hours of stability, Medtronic Evera MRI XT DR SureScanTM Series DDMB2D1 implantable cardiovertor-defibrillator was implanted. During implantation, patient had ventricular fibrillation requiring prolonged (Comprehensive Cardiac Rehabilitation) CCR for 45 minutes. Post-procedure, he remained comatose for more than 48 hours. Bedside EEG showed mild to moderate generalised encephalopathy which did not match the clinical picture. Therefore, MRI brain was done on fourth day after implant taking risk consent from the patient’s wife. The MRI scan was done safely using SureScan mode. It showed mild changes of hypoxic encephalopathy suggesting a decent prognosis. The ICD lead positions and parameters were rechecked and found to be optimum. The patient slowly recovered over three weeks. He needed dialysis for acute kidney injury, antibiotics for ventilator associated pneumonia, tracheostomy for ventilation and percutaneous endoscopic gastrostomy for feeding. He was discharged with percutaneous endoscopic gastrostomy (PEG) in-situ and improving neurological status. Conclusion: While a single case cannot make a recommendation, this case demonstrates that it not impossible to do an MRI scan safely in a patient very shortly after an ICD implant if the clinical situation warrants it.

Implantable cardioverter-defibrillator ventricular tachycardia MRI scan hypoxic ischaemic encephalopathy.

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.