Experimental Investigation of the Performance and Energy Consumption of an Automated Ice-cube Making Machine
Rasheed Ayofe Shittu, Isaac Femi Titiladunayo
Journal of Engineering Research and Reports · pp. 1–12 · Published 17 Nov 2018
10.9734/jerr/2018/v3i116700Abstract
Aims: This study investigates the performance of a developed automated ice-cube making machine under controlled ambient conditions, in which its energy usage, rate of ice cube production and refrigeration system performance was analysed. Study Design: Average ambient temperatures of 24°C and 32°C were considered for investigation in order to determine their influence on ice production capacity, rate of ice-cube making and energy consumption. The choice of the ambient temperature is based on the extreme ambient conditions under which the machine is designed to operate in a wide range of geographical regions. The refrigeration system performance was carried out under normal room temperature (average of 23°C). Place and Duration of Study: Department of Mechanical Engineering, Federal University of Technology Akure, Ondo State Central Workshop, Between December 2017 and January 2018. Methodology: The machine was set into operation for 5 consecutive ice production cycle during which the ice making time, harvest time, quantity of ice produced and energy consumption were recorded. Results: The ice production capacity, harvesting time and energy consumption show various dissimilarities at both temperatures. 0.618 kg of ice cubes were produced within an ice making cycle of 34.9 minutes, harvesting time of 1.28 minutes and total energy consumption of 0.14053 kWh at 24°C while at 32°C, the machine produced an average of 0.612 kg ice cubes within an ice making cycle of 38.5 minutes harvesting time 1.21 minutes and energy consumption of 0.15947 kWh respectively. Consequently, 13.5% more energy is consumed, with about 1% less quantity of ice produced at 32°C than at 24°C per ice production cycle. Conclusion: Therefore, the ice making capacity of the developed machine suggests that the temperature of the environment has a strong influence on the energy consumption, but little effect on the quantity of ice produced per cycle. The refrigeration system cycle performance analysis results showed a considerably high cooling capacity of 0.379 kW during the ice-making cycle with a corresponding coefficient of performance (COP) of 2.23, and a heating capacity of 2.24 kW during the harvest cycle with a corresponding COP of 8.21. The results obtained showed that the machine is reliable in operation with minimal energy consumption.
Cited by 2
2 citations reported by external sources — individual citing-article records aren't available to list yet.
Related research
- Comparison of Automated System Vitek-2 with Conventional Methods, for Identification and Antibiotic Sensitivity in Gram Negative Organisms — shares topic coverage
- Dynamics of the Digital Workforce: Assessing the Interplay and Impact of AI, Automation, and Employment Policies — shares topic coverage
- An Olive Oil Tank Farm Management and Optimum Blend System — shares topic coverage
- Starting Age Zero-Based Excel Automation of Optimal Policy Prescriptions and Returns for Machine Replacement Problems with Stationary Data and Age Transition Perspectives — shares topic coverage
- Automation in Agriculture Libraries: Trends, Technologies and Future Prospects — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.