Skip to content
Research Article Open access CC BY 4.0

Microbial Assessment of Indoor Air Quality of Ventilation Systems

H. O. Stanley, B. Onwuna, C. J. Ugboma

Asian Journal of Advanced Research and Reports · pp. 1–7 · Published 13 Mar 2019

10.9734/ajarr/2019/v3i430095

Abstract

The aim of the study was to compare the indoor levels of airborne bacteria and fungi of air conditioned (AC) buildings and naturally ventilated (NV) buildings using a Supermarket, a Laboratory and an Eatery as a case study. The predominant bacterial isolates were Staphylococcus, Micrococcus spp., Escherichia coli, Bacillus spp., Streptococcus spp., Enterococcus spp., Klebsiella spp. The fungal isolates belong to the genera Penicillium, Aspergillus, Mucor, Trichophyton, Fusarium, Candida and Chaetomium. The levels of airborne bacteria and fungi were determined using settle plate method. In AC buildings the average air levels of bacteria (supermarket: 24.2 CFU m-3; laboratory: 29.2 CFU m-3; eatery: 51.0 CFU m-3 air) were higher than in NV (respectively: 54.3 CFU m-3; 100.7 CFU m-3; 134.3 CFU m-3 air). The average air levels for fungal isolates were higher in the eatery due to presence of poorly maintained AC system (supermarket: 7.8 CFU m-3; laboratory: 11.5 CFU m-3; eatery: 56.7 CFU m-3 air) than in NV (28.6 CFU m-3; 19.6 CFU m-3; 13.5 CFU m-3 air respectively). Findings from this study showed that AC buildings had lower levels of bacterial and fungal contamination compared to buildings with natural ventilation.

Air conditioned buildings naturally ventilated buildings bacteria fungi

Cited by 4

Phylogenetic Identification, Diversity, and Richness of Aspergillus from Homes in Havana, Cuba

Kenia C. Sánchez Espinosa, Michel Almaguer Chávez, Esperanza Duarte-Escalante · Microorganisms · 2021

Physical parameters influence the microbial quality of indoor air in research laboratories: A report from Malaysia

Kuilan Yogeswaran, Liyana Azmi, Subha Bhassu · Kuwait Journal of Science · 2023

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

4

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.