Skip to content
Research Article Open access CC BY 4.0

A Design and Mathematical Modeling of the Novel L(LCL)₃ Hybrid Low-Pass Filter for Power Grid-Connected Solar PV Systems

Unogwu, Daniel Ogbu, Samson Dauda Yusuf, Abdulmumini Zubairu Loko

Asian Journal of Advanced Research and Reports · pp. 47–69 · Published 25 Jun 2026

10.9734/ajarr/2026/v20i71400

Abstract

In the face of depleting natural resources, the efficient use of available energy sources is becoming increasingly important in reducing operational costs while satisfying ever-tighter pollution regulations. This paper presents the complete mathematical design framework and component-calculation methodology for the L(LCL)₃ filter, a novel high-order hybrid low-pass filter topology developed for the integration of utility-scale solar photovoltaic (PV) systems into high-voltage grid networks. The L(LCL)₃ filter extends the established LCL and LLCL filter architectures by incorporating three resonant trap circuits tuned to the inverter switching frequency (fsw=10 kHz), its second harmonic (20 kHz), and a third attenuation band between four series inductors (L1,L2,L3,L4) distributed in a 0.40:0.25:0.20:0.15 ratio. The design employs a rigorous per-unit system analysis using HVDC-class constraints: total inductance ≤ 8% of base inductance, total capacitance ≤ 3% of base capacitance (limiting reactive power to ≤ 3 MVAr), and current ripple ≤ 20% of base current. For a 100 MVA, 33 kV reference system with fgrid = 50 Hz and fsw=10 kHz, complete component calculations yield: L1 = 1.108 mH,L2 = 0.693 mH,L3 = 0.554 mH,L4 = 0.416 mH; C1 = 1.3 µF,C2 = 0.36 µF,C3 = 0.11 µF and damping network parameters Rd1 = 6.0 Ω,Rd2 = 4.0 Ω, Rd3 = 3.0 Ω, Rd4 = 2.0 Ω. The filter achieves a damping ratio ζ = 0.196 and quality factor Q = 2.55, ensuring well-damped operation with a primary resonance at 8,011 Hz. Resonance analysis confirms trap frequencies of 10,078 Hz (Trap 1) and 20,396 Hz (Trap 2) with less than 2% design error. MATLAB/Simulink simulation confirmed the analytical claims of grid-side THD 1.3% and primary resonance frequency within 3% of the analytically derived values, with filter efficiency exceeding 99.0% under rated operating conditions. The mathematical framework is presented in sufficient detail for direct replication and adaptation to other power ratings.

L(LCL)₃ filter hybrid low-pass filter grid-connected inverter solar photovoltaic system harmonic attenuation resonant trap circuit passive damping network total harmonic distortion MATLAB/Simulink validation utility-scale power grid

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.