Comparative Analysis of Rescaled Range Results of Normal and Abnormal Heart Sound Recordings
Lotachukwu Ibe, Tajudeen Abiola Ogunniyi Salau
Journal of Engineering Research and Reports · pp. 1–7 · Published 15 Oct 2019
10.9734/jerr/2019/v7i316971Abstract
Heart acoustics can be used as an early diagnostic tool, to quickly and accurately identify medical patients who may be at risk of unfavourable cardiovascular outcomes. However, at present, there remains no universally accepted standard or technique for detecting abnormalities using Phonocardiograms. To address this, a large database containing normal and abnormal heart sound recordings of patients were studied with the rescaled range technique and the Hurst exponent, a measure of persistence for non-linear dynamic data. Using the Hurst exponent (H) as a benchmark, we compared the values of the Hurst exponent for normal heart sound recordings with that of the abnormal heart sound recordings. For this study, the recording length was limited to the first 10 seconds for all 578 distinct recordings, which were selected randomly from the database. Furthermore, two Hurst exponent values were obtained for each recording, by subjecting them to time intervals of 1 and 2 milliseconds respectively. The results from this study show that heart sound recordings are persistent (H > 0.5) for normal and abnormal heart sound recordings, with the normal recordings being slightly more persistent.
Cited by 1
Farhan Naufal Rifqi, Nurul Shazana Abdul Hamid, A. Babatunde Rabiu · Universe · 2021
Related research
- Detection and Molecular Identification of Persistent Water Vessel Colonizing Bacteria in a Table Water Factory in Nigeria — shares topic coverage
- Soil Persistence of Diuron Applied to Cotton Cultivation in Red and Black Soils — shares topic coverage
- Drought Frequency and Persistence in the Upper River Tana Basin in Kenya — shares topic coverage
- Development of Bait for the Management of Coffee Bean Weevil, Araecerus fasciculatus in Stored Cocoa — shares topic coverage
- Ultimate Fate and Determination of Pyriproxyfen and Fenpropathrin in the Environment: A Critical Review — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.