Skip to content
Research Article Open access CC BY 4.0

A Simple and Sensitive LC-MS/MS Method for Determination and Quantification of Potential Genotoxic Impurities in the Vismodegib Active Pharmaceutical Ingredient

Rayala Rama Rao, Gundapaneni Ravi Kumar, Vadde Megha Vardhan, Veeraswami Boddu

Journal of Pharmaceutical Research International · pp. 88–102 · Published 21 Sep 2021

10.9734/jpri/2021/v33i44B32654

Abstract

A rapid and sensitive LC-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of four potential genotoxic impurities Imp-A (2-chloro-5-nitroaniline), Imp-B (1-chloro-2-iodo-4-nitrobenzene), Imp-C (1-(2-chloro-5-nitrophenyl)ethan-1-one) and Imp-D (2-chloro-5-nitrobenzoic acid) in Vismodegib API drug sample. This trace analysis was achieved on CSH C18, 15.0 cm x 3.0 mm, 1.7 micron column maintained at 45°C. Optimal mobile phase consisted of 0.05% formic acid in water was used as mobile phase A and acetonitrile used as mobile phase B in gradient mode with the flow rate of 0.5 mL/min. The developed method had the short run time of 12 minutes. Quantification of four potential genotoxic impurities were carried out using mass detection with electrospray ionization in multiple reaction monitoring mode. The method was linear in the range of 0.03 ppm to 1.50 ppm for four potential genotoxic impurities with a correlation coefficient not less than 0.999. The recoveries were found satisfactory over the range between 96.67 and 106.90% for all selected impurities. The developed method was able to quantitate all four PGIs at a concentration level of 0.03 ppm (0.03 ppm with respect to 20 mg /mL Vismodegib).

Potential genotoxic impurities (PGIs) LC-MS/MS low level Vismodegib

Cited by 2

Review on Nitrosamine: A Potential Genotoxic Impurity

Baratam Kasinath, Boddu Veeraswami · Research Journal of Pharmacy and Technology · 2025

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.