Thermodynamic Analysis of Two-stage Vapour Compression Refrigeration Systems Using Eco-friendly Refrigerants
A.A. Aderibigbe, A.D. Ogunsola, E.A. Fadiji, I.A. Babatunde, O. Adeyi, A.J. Adeyi, E.A. Owoo
Journal of Energy Research and Reviews · pp. 61–71 · Published 30 Dec 2024
10.9734/jenrr/2024/v16i12387Abstract
As Nigeria continues to expand its industrial, commercial, and residential cooling needs, the demand for efficient and environmentally sustainable refrigeration systems is growing. However, the environmental impact of conventional refrigerants has raised concerns due to their high global warming potential and ozone depletion potential. This study presents a thermodynamic analysis of two-stage vapour compression refrigeration systems in Nigeria, utilizing eco-friendly refrigerants which offer low global warming potential and zero ozone depletion potential. The refrigeration system comprises a high-pressure stage compressor and a low-pressure stage compressor with the inter stage pressure taken to be the ideal inter stage pressure. Performance analysis of R-717, R-600, R-600a and R-290 two-stage vapour compression refrigeration systems were made using seven parameters. The effect of the variation of five operating/design parameters (evaporating temperature, condensing temperature, superheating temperature, sub cooling temperature and refrigerant mass flow rate) on Coefficient of Performance (COP) of two-stage vapour compression system was analysed using engineering equation solver software. The results showed that as evaporating temperature decreases from 0oC to -50oC, COP decreased for all the four refrigerants considered. R-717 gave the highest COP value of 7.636 at evaporating temperature of 0oC while R-600a gave the lowest value of 4.009 at the same temperature. The results also showed that the COP of all the four refrigerants increased with increase in sub cooling temperature and Superheating Temperature, whereas it decreased with increase in condensing temperature. The study revealed that, except for the mass flow rate, all other operating parameters significantly affect the COP of refrigeration systems considered.
Cited by 1
1 citation reported by external sources — individual citing-article records aren't available to list yet.
Related research
- Effect of Throttling Variation on the Performance of Vapour Compression Refrigeration System — shares topic coverage
- Performance Evaluation of LiBr-H2O Vapours Absorption System for an Office Building Cooling — shares topic coverage
- Thermodynamic Analysis of Single-Stage Vapour Compression Refrigeration System in Nigeria Using Natural Refrigerants — shares topic coverage
- Design and Analysis of a Thermoelectric Air-conditioning System — shares topic coverage
- Wind Energy Production from Vertical Axis Wind Turbine on Offshore Production Platforms in Trinidad — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.