Skip to content
Research Article Open access CC BY 4.0

Thermodynamic Analysis of Two-stage Vapour Compression Refrigeration Systems Using Eco-friendly Refrigerants

A.A. Aderibigbe, A.D. Ogunsola, E.A. Fadiji, I.A. Babatunde, O. Adeyi, A.J. Adeyi, E.A. Owoo

Journal of Energy Research and Reviews · pp. 61–71 · Published 30 Dec 2024

10.9734/jenrr/2024/v16i12387

Abstract

As Nigeria continues to expand its industrial, commercial, and residential cooling needs, the demand for efficient and environmentally sustainable refrigeration systems is growing. However, the environmental impact of conventional refrigerants has raised concerns due to their high global warming potential and ozone depletion potential. This study presents a thermodynamic analysis of two-stage vapour compression refrigeration systems in Nigeria, utilizing eco-friendly refrigerants which offer low global warming potential and zero ozone depletion potential. The refrigeration system comprises a high-pressure stage compressor and a low-pressure stage compressor with the inter stage pressure taken to be the ideal inter stage pressure. Performance analysis of R-717, R-600, R-600a and R-290 two-stage vapour compression refrigeration systems were made using seven parameters. The effect of the variation of five operating/design parameters (evaporating temperature, condensing temperature, superheating temperature, sub cooling temperature and refrigerant mass flow rate) on Coefficient of Performance (COP) of two-stage vapour compression system was analysed using engineering equation solver software. The results showed that as evaporating temperature decreases from 0oC to -50oC, COP decreased for all the four refrigerants considered. R-717 gave the highest COP value of 7.636 at evaporating temperature of 0oC while R-600a gave the lowest value of 4.009 at the same temperature. The results also showed that the COP of all the four refrigerants increased with increase in sub cooling temperature and Superheating Temperature, whereas it decreased with increase in condensing temperature. The study revealed that, except for the mass flow rate, all other operating parameters significantly affect the COP of refrigeration systems considered.

Coefficient of performance sub cooling superheating eco-friendly two-stage

Cited by 1

1 citation reported by external sources — individual citing-article records aren't available to list yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.