Skip to content
Research Article Open access CC BY 4.0

Assessment of Nasopharyngeal Changes Following MARPE and Self-ligating Appliance Treatments: A CBCT-based Study

Andréa Michelle dos Reis Gomes, Tiago Fialho, Cecilia Maria Marin Ramirez, Aldo Otazu, Dino Marcelo Torres, José Eduardo Prado de Souza, Fabricio Pinelli Valarelli, Paula Cotrin, Célia Regina Maio Pinzan-Vercelino, Karina Maria Salvatore Freitas

Journal of Advances in Medicine and Medical Research · pp. 157–165 · Published 2 Sep 2024

10.9734/jammr/2024/v36i95565

Abstract

Objective: The objective of this study was to compare the sagittal area, minimum axial area and volume of the nasopharynx after treatment with MARPE and self-ligating appliances. Materials and Methods: The sample consisted of documentation and initial and final CT scans of 37 patients with Class I malocclusion treated without extraction, divided into 2 groups: Group 1 (Self-ligating): 21 patients, mean age of 19.55 years (s.d.=1.31), 11 men and 10 women, with moderate dental crowding, presence of maxillary atresia and treated with self-ligating fixed appliance Damon 3MX. Group 2 (MARPE): 16 patients, with a mean age of 24.92 years (s.d.=7.60), 11 women and 5 men, with the presence of maxillary atresia and posterior crossbite and treated with mini-implant anchored rapid maxillary expansion (MARPE). The Dolphin Imaging 3D software was used to assess nasopharyngeal changes using CBCT scans before and after treatment with MARPE and after leveling with self-ligating appliances. Intergroup comparison was performed using the independent t-test. Results: The MARPE group showed a statistically greater increase in all nasopharyngeal measurements, ie, sagittal area, minimum axial area and volume, with treatment, than the self-ligating group. Conclusion: Miniscrew-supported rapid maxillary expansion (MARPE) achieved better results with a greater increase in all nasopharyngeal measurements than self-ligating appliances.

Orthodontic anchorage procedures airway management cone beam computed tomography fixed orthodontic appliances

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.