Comparative Evaluation of Fracture Resistance and Microleakage of Reattached Anterior Tooth Fragment Using Two Different Flowable Composites- An in vitro Study

Saumya ., Renuka Dhingra, Anil Gupta, Busi Karunanand

Journal of Advances in Medicine and Medical Research · pp. 1–10 · Published 18 May 2017

10.9734/BJMMR/2017/32526

Abstract

Aim: To evaluate and compare the fracture resistance and microleakage of reattached anterior tooth fragment using two different flowable composites. Study Design: In-vitro study. Place and Duration of Study: The present in vitro study was carried out in the Department of Pedodontics and Preventive Dentistry, Faculty of Dental Sciences, SGT University, between June 2014 and July 2016. Methodology: The subjects were selected from various sources. A total of 160 extracted permanent anteriors were selected for the study. Teeth were divided into 2 groups, 80 teeth in each group reattached with G-aenial Universal Flo and Esthet X-Flow, evaluated for fracture resistance testing using Universal testing machine. Half number of teeth tested for microleakage using Dye-penetration method. The results obtained from the study were then tabulated and statistically analyzed. Results: Mean value for fracture resistance in Group I were observed (89.07 ± 32.46) whereas in Group II were observed (64.63 ± 40.33). On statistical analysis result found to be highly significant (p = 0.001). Out of 40 teeth, in Group I -16 observed no penetration whereas in Group II -10 teeth were observed no penetration. On Enamel-Dentin microleakage in Group I found to be in 6 teeth, whereas 14 teeth showed the same Enamel-Dentin penetration in Group II. But on statistical analysis, overall result found to be non-significant (p = 0.19). Conclusion: Among the tested flowable composites, G-aenial Universal Flo showed highly significant fracture resistance than Esthet X-flow. Microleakage shows no significant differences between nanohybrid and microhybrid flowable composites.

Reattachment of tooth fragment Fracture resistance microleakage flowable composite

Cited by 1

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.