Glycated Hemoglobin Evaluation by Means of Ion Exchange Chromatography and Immunoassay in Normal and Hemoglobinopathy Patients
International Blood Research & Reviews · pp. 1–9 · Published 24 Feb 2016
10.9734/IBRR/2016/24410Abstract
Aims and Objectives: High performance liquid chromatography which is basically an Ion Exchange Chromatography, is the most popular as well as expensive method for glycated hemoglobin estimation but biased results have been observed in hemoglobinopathies. Sometimes results cannot be reported also. In such situation the laboratory adopted immunoassay method and successfully reported the results. Therefore, a comparative analysis of glycated hemoglobin results of normal and abnormal hemoglobin were essential as high performance liquid chromatography is the most sought after method. Study Design: Number of patients with normal adult hemoglobin compared were 120. Patients with Hb-AE thalassemia were 21. Patients with β-thalassemia trait were 36. Hb-E-β thalassemia patients were 6, β-thalassemia homozygous 10 and HbSS patients tested were 4. The glycated hemoglobin values obtained were from euglycemic to severe diabetic range. The instruments used for measurement are D10 BIORAD and Cobas Integra 400plus. Data Analysis: Deviations calculated from results of same patient obtained from two system. Regression coefficients of each group were calculated. Trend analysis was done and graphically presented. Results and Discussion: Regression analysis of normal, HbAE&β-variant patients show coefficients are 0.988,0.976 &0.961 respectively proving excellent comparability of two methods. But trend analysis of deviations show right shift of 85%HbAE& 86.1%β-variants .Similar bias was observed in external quality assessment results also. The immunoassay results were comparable with boronate affinity chromatography and enzymatic estimation method. The deviation in HPLC observed only when in external assessment sample a window was seen. Therefore, observations of the trend of patients and EQAS sample indicates low bias of HbA1c estimation by HPLC method in D10.In severe forms of Hemoglobinopathy i.e. HbSS, Hb-E-β and β-thalassemia homozygous 75%,67% & 60% results could not be obtained from D10. The acceptability of immunoassay results checked by comparing glucose fasting and estimated average glucose calculation values. Conclusion: Immunoassay, the second popular method is reliable, less expensive method and results remain unaffected in hemoglobinopathies.
Cited by 0
No indexed citations yet.
Related research
- Association of Serum Bilirubin and Serum Uric Acid with Glycemic Status in Type 2 Diabetes Mellitus — shares topic coverage
- Novel Biomarkers for Early Detection and Metabolic Profiling in Diabetes and Prediabetes — shares topic coverage
- Correlation of Glucose Tolerance Disorders with Glycated Albumin and HbA1c in Transfusion‑Dependent Children with Beta Thalassemia — shares topic coverage
- Prolonged Effect of Niger Delta Honey on Blood Glucose and Haematological Parameters in Alloxan Induced Diabetic Rats — shares topic coverage
- Behaviour of Fetal Haemoglobin and Its Correlation to Haemoglobin A1c Levels in Sudanese Adult Insulin-Dependent Diabetes Mellitus Patients — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.