The aim of this study was to develop an energy efficient method to decompose powdered laboratory safety examination gloves (PLEG). This paper reports on the results of thermogravimetric analysis (TGA) of PLEG without a catalyst. The study was conducted in the Department of Biological and Physical Sciences at South Carolina State University (SCSU), Orangeburg, SC, USA, during the spring of 2014. Twelve samples of PLEG were studied under three types of operating conditions. First a sample was scanned from 50°C to 800°C with a heating rate of 10°C/min while it was purged with 10 mL/min argon. The results of this study determined the thermal stability of PLEG and the temperature of highest weight loss rate (~410°C). The second approach used two sequential dynamic thermal scans with a linear and fast (200°C/min) increase of the temperature over time, and two sequential isothermal steps for 30 minutes; one below 410°C and the other at 410°C. The third approach used a dynamic thermal scan and a sequential isothermal step for 30 minutes at a temperature over 410°C. From the thermal scans and isotherms, the highest rate of weight loss, the temperature at the maximum weight loss, the acceleration of weight loss by thermal scan, the deceleration of weight loss at the isotherms, the rate constant and the activation energy of weight loss (Ea) were estimated. The experimental results confirmed that Ea of weight loss of the PLEG samples depended on the temperature of operation. At temperatures below 430°, the amount of Ea for the weight loss of sample were higher than those above 430°C temperatures. Also, internal reactions of the sample of PLEG at 340°C resulted on thermally stable materials, which slowed down the thermolysis rate of the sample at higher temperatures.

Thermogravimetric latex-gloves kinetics environment pollution pyrolysis thermolysis neoprene activation-energy rate-constant

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.