Prediction of Retention in Gradient Reversed-Phase Liquid Chromatography for Phenyl Isothiocyanate-Derivatives of Amino Acids
Jelena Golushko, Svetlana Vorslova, Sergey Galushko, Arturs Viksna, Kristine Edolfa
Chemical Science International Journal · pp. 14–23 · Published 4 Oct 2013
10.9734/ACSJ/2014/6299Abstract
Aim: To study the applicability of the solvatic retention model for the prediction of retention times in gradient elution of phenylisothiocyanate derivatives of natural amino acids. Methodology: The solvatic retention model of reversed-phase liquid chromatography has been used to predict retention of phenylisothiocyanate derivatives of 25 natural amino acids under conditions of gradient elution. Retention factors have been calculated from molecular parameters of the structures of analytes and the characteristics of a column and an eluent using the ChromSword software package. Results: The modeled initial estimation of retention time was found to be within 4% of the experimentally determined retention time. Fine-tuning of the model parameters using data from experimental runs further improved the accuracy of the model. Conclusion: A step-by-step method which includes the first-guess prediction of initial conditions from structural formula and fine tuning parameters of the retention model using data from successive runs can save time in method development and optimization of the separation of target compounds.
Cited by 1
Svetlana Vorslova, Jelena Golushko, Sergey Galushko · Chromatographia · 2014
Related research
- Pesticide Residues Monitoring of Organophosphorus and Carbamates in Grapes in Three Egyptian Governorates — shares topic coverage
- Efficiency of Solvatic Sorption Model for Predicting the Retention in Multi-step Gradient RP-LC with Different Stationary Phases — shares topic coverage
- Relative Analysis of Gallic-Acid, Theobromine, Theophylline, and Caffeine Content among 12 Bangladeshi Tea Genotypes Using Reversed-Phase Liquid Chromatography — shares topic coverage
- A 100% Water Mobile Phase HPLC-PDA Analysis of Tetracycline Antibiotics — shares topic coverage
- Development of ZrO2-Coated SPME Fibers for Detecting Benzotriazole Ultraviolet Filters in Water Samples — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.