Skip to content
Research Article Open access CC BY 4.0

Hemodialysis-associated Oxidative Stress: Comparison of Helixone® and Polysulfone® Dialyzer

Mourad Errasfa, Fatima Zahra Batta, Kaoutar Alaoui Sekkouri, Chakib Maaroufi, Mohamed Arrayhani, Tarik Sqalli Houssaini

Journal of Advances in Medical and Pharmaceutical Sciences · pp. 1–7 · Published 3 Mar 2016

10.9734/JAMPS/2016/24141

Abstract

Background: Patients at end stage renal failure require hemodialysis, a process that contributes to oxidative stress, where the quality of hemodialysis membrane plays a key role. Aim of the Study: We sought to investigate the effect of two different hemodialysis membranes (Helixone® vs Polysulfone®) on several blood biologic and oxidative stress parameters. Patients and Methods: Among 86 patients of our hemodialysis facility at the University Hospital, 12 patients were included in the study according to inclusion and exclusion criteria. Patients used Polysulfone® membrane in a first step of the study, then they switched to Helixone® membrane. Under the two kinds of membranes, we measured routine biologic parameters, and pre- and post- dialysis plasma oxidative stress parameters (malondialdehyde and Total Anti-Oxidant Activity, as assessed respectively, by the method of thiobarbituric acid, and an anti-oxidant activity commercial kit). Results: With both Polysulfone® and Helixone® dialyzers, there was an important and significant increase of malondialdehyde upon a single hemodialysis session, however, the increase of malondialdehyde concentration was significantly reduced with Helixone® dialyzer as compared to Polysulfone® one. Plasma total anti-oxidant activity was reduced significantly upon a single hemodialysis session with both dialyzers, however, such a reduction was significantly higher with Polysulfone® (28% reduction) than with Helixone® (11.7% reduction) dialyzer. The levels of other routine blood parameters related to the performance of dialysis process (urea, uric acid, creatinine) under both dialyzers were similar. Conclusion: Hemodialysis-associated oxidative stress, as assessed by MDA concentration and plasma total anti-oxidant activity, seems to be significantly reduced with Helixone® dialyzer when compared to Polysulfone® dialyzer. This difference may bring positive impact on hemodialysis-associated side effects on cardiovascular and cerebrovascular systems.  

Hemodialysis membrane dialyzer oxidative stress malondialdehyde

References (25)

  1. 1 Assay for lipid peroxides in animal tissues by thiobarbituric acid reaction [DOI]
  2. 2 Chronic Kidney Disease and the Risks of Death, Cardiovascular Events, and Hospitalization [DOI]
  3. 3 Advanced oxidation protein products as a novel marker of oxidative stress in uremia [DOI]
  4. 4 Lipid peroxidation and antioxidants as biomarkers of tissue damage [DOI]
  5. 5 Biomarkers of Oxidative Damage in Human Disease [DOI]
  6. 6 Inflammation enhances cardiovascular risk and mortality in hemodialysis patients [DOI]
  7. 7 Plasma malondialdehyde as biomarker for oxidative stress: reference interval and effects of life-style factors [DOI]
  8. 8 Lipoperoxides in plasma as measured by liquid-chromatographic separation of malondialdehyde-thiobarbituric acid adduct. [DOI]
  9. 9 Effect of membrane composition and structure on solute removal and biocompatibility in hemodialysis [DOI]
  10. 10 Advanced Oxidation Protein Products Accelerate Atherosclerosis Through Promoting Oxidative Stress and Inflammation [DOI]
  11. 11 Alteration in plasma antioxidant capacities in chronic renal failure and hemodialysis patients: a possible explanation for the increased cardiovascular risk in these patients [DOI]
  12. 12 Effect of hemodialysis on total antioxidant capacity and serum antioxidants in patients with chronic renal failure [DOI]
  13. 13 Alteration in plasma antioxidant capacity in various degrees of chronic renal failure.
  14. 14 Myeloperoxidase serves as a marker of oxidative stress during single haemodialysis session using two different biocompatible dialysis membranes [DOI]
  15. 15 Inflammation and Oxidative Stress in End-Stage Renal Disease Patients Treated with Hemodialysis or Peritoneal Dialysis [DOI]
  16. 16 Protein Oxidative Stress and Dyslipidemia in Dialysis Patients [DOI]
  17. 17 Oxidative Stress and Antioxidative Enzyme Activities in Chronic Kidney Disease and Different Types of Renal Replacement Therapy [DOI]
  18. 18 An Overview of Haemodialysis and Oxidant Stress [DOI]
  19. 19 Hemodialyzer: From macro-design to membrane nanostructure; the case of the FX-class of hemodialyzers [DOI]
  20. 20 Effect of Dialysis on Plasma Total Antioxidant Capacity and Lipid Peroxidation Products in Patients with End-Stage Renal Failure [DOI]
  21. 21 Review: Membranes for haemodialysis [DOI]
  22. 22 Changes in serum markers of oxidative stress with varying periods of haemodialysis [DOI]
  23. 23 Reactive Oxygen Metabolites: A Link between Oxidative Stress and Inflammation in Patients on Hemodialysis [DOI]
  24. 24 Oxidative Stress Markers and C-Reactive Protein in Pediatric Patients on Hemodialysis [DOI]
  25. 25 Impact of Improving Quality of Dialysis Fluid on Oxidative Stress and Lipid Profile in Hemodialysis Patients [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

58

Page views

0

PDF downloads

35

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.