Aims: A simple and sensitive high performance liquid chromatographic (HPLC) method was developed for quantification of salbutamol in rat plasma. Terbutaline was used as an internal standard (IS). Study Design: Validation study. Methodology: The present method used solid phase extraction of salbutamol from rat plasma. Chromatographic separation achieved isocratically on reversed-phase c18 column (250 × 4.6 mm, 5μ) and the column effluent was monitored by uv detector at 276 nm. The mobile phase used was acetonitrile: 50mm ammonium acetate (ph 7.0), (80: 20 % v/v) at a flow rate of 1.0 ml/min. Results and Discussion: This method was linear over the range of 50.0 – 1000.0 ng/ml with regression coefficient greater than 0.99. Conclusion: The method was found to be precise, accurate and specific during the study. The simplicity of the method allows for application in laboratories that lack sophisticated analytical instruments such as LC–MS/MS or GC–MS/MS that are complicated, costly and time consuming rather than a simple HPLC–UV method. The method was successfully applied for pharmacokinetic study of salbutamol in rats.

Simple Method high performance liquid chromatography validation salbutamol rat plasma pharmacokinetic study.

Cited by 4

A Statistical-based Stability-Indicating Assay for the Estimation of Salbutamol and Ketotifen using HPLC and HPTLC Methods

Manik Ghosh, Reetu Bandewar, Arijit Mondal · Current Spectroscopy and Chromatography · 2024

Green potentiometric electrode for determination of salbutamol in biological samples

Heba T. Elbalkiny, Ahmed Samir · Analytical Biochemistry · 2022

Showing 3 of 4 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

4

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.