Chest CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian
U. Rilwan, G. C. Onuchukwu, I. Umar, L. K. Sabiu, H. A. Abdullahi
Asian Journal of Advanced Research and Reports · pp. 1–9 · Published 27 Jan 2020
10.9734/ajarr/2020/v8i230193Abstract
The term "computed tomography" (CT) is often used to refer to X-ray CT, because it is the most commonly known form. But, many other types of CT exist, such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). This study was carried out in the north central part of Nigeria which includes Abuja and Keffi (Nasarawa State). This study has established local diagnostic reference levels (LDRLs). Dose report and scan parameters for chest was assessed during the period (January – July, 2016) of seven months at the three study centres (A, B and C in which two are located in Abuja and the other one (C) located in Keffi. Data on CT Dose index (CTDIw) and dose length product (DLP) available and achieved on CT scanner control console was recorded for a minimum of 10 average sized patients for each facility to established a local Diagnostic reference level (LDRLs) and radiation dose optimization Data was collected using a purposive sampling technique, from 131 adult patients weighing 70±3kg) from Philip brilliance, Toshiba Alexion and General Electric (GE) CT scanners for this study. Third quartile values of the estimated LDRLs for CTDIw and DLP was determined as 10.9 mGy and 432.8 mCy*cm. The mean CTDIw obtained are lower to the reported data from the European Commission of 30mGy. The mean DLP are comparably lower than all the reported value from the European commission of 650mGy/cm. Therefore, there is no any clinical implication and hence CT dose optimization is recommended.
Cited by 1
Prisca Onyinye Ukoha, Felicitas Ugochinyere Idigo, Mark Chukwudi Okeji · Radiation Physics and Chemistry · 2023
Related research
- Analysis of Acceptance of Radiation Doses for Radiation Workers in the Radiology Facility of Bali Mandara Hospital — shares topic coverage
- Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Abdominal CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
- Head CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.