Comparison for Kmean and Astigmatism for Orbscan IIz and Pentacam at Different Stages of Keratoconus - A Clinical Study
Ophthalmology Research: An International Journal · pp. 30–40 · Published 11 Jul 2020
10.9734/or/2020/v13i130160Abstract
Aims: To compare results of Orbscan IIz and Pentacam at different stages of keratoconus on Kmean and Astigmatism. Sample and Study Design: 94 keratoconus patients were included in the study, of which 52 were men and 42 women. Keratoconus patients were screened with Orbscan IIz and Pentacam before undergoing corneal collagen cross-linking. The patients were distributed according to different keratoconus stages. Place and Duration of Study: University of West Attica Dept Biomedical Sciensce Course Optics & Optometry in collaboration with Athens “Ophthalmiatrio” Clinic during the period between October 2017 to January 2019. Methodology: Topographic maps correlation of two types of corneal topographers Orbscan IIz and Pentacam. The Kmean values and the Astigmatism presented at different stages of keratoconus were compared. Results: A Sample of 188 eyes were measured having, 20 eyes (10.6%) with subclinical keratoconus, the correlation coefficient r for Kmean values between Orbscan IIz and Pentacam was 0.9758 (P<0.0001), 44 eyes (23.3%) at stage 1 with the correlation coefficient r=0.8482 (P<0.0001), 33 eyes (17.6%) at stage 2 with the correlation coefficient r=0.8147 (P<0.0001), 67 eyes (35.6%) at stage 3 with the correlation coefficient r=0.797 (P<0.0001), 10 eyes (5.3%) at stage 4 with the correlation coefficient r=0.8455 (P=0.0021), 8 eyes (4.4%) with iatrogenic keratoectasia after refractive surgery having correlation coefficient r=0.928 (P=0.0009). Conclusion: Statistical differences between Orbscan IIz and Pentacam were found for Kmean in all stages of keratoconus. The performance for Kmean measurement of the corneal topographers Orbscan IIz and Pentacam is satisfactory for both systems in various stages of keratoconus having a very strong correlation (Correlation coefficient r ranged from 0.9758 to 0.7970). Statistical differences between Orbscan IIz and Pentacam were evident also at the Astigmatism measurements at stage 3 and 4.
Cited by 0
No indexed citations yet.
Related research
- Changes in Anterior Segment Parameters after Penetrating Keratoplasty for Keratoconus — shares topic coverage
- Comparison between OrbscanIIz, Pentacam, Ultrasound Pachymetry (Tomey SP-100) at Different Stages of Keratoconus — shares topic coverage
- Comparative Study of Anterior Chamber Angle and Depth Recorded with Pentacam and AS-OCT SD “Spectralis” — shares topic coverage
- The Influence of Horizontal Corneal Diameter on Corneal Tomography and Belin/Ambrósio Enhanced Ectasia Display of Pentacam Corneal Tomography — shares topic coverage
- Keratoconus Plus (KC-Plus): A New Term Proposed by an Egyptian Research Team for Use in Relation to Keratoconus, with Coexisting Cataract — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.