Patient Dose Assessment for Common Digital Diagnostic Radiology Examination in Hamad Medical Corporation Hospitals in the State of Qatar
Huda M. Al-Naemi, Ibrahim I. Abdallah, Osman B. Taha, Mahmoud A. Tarabieh, Nabil A. Iqeilan, Samya M. Al-Manea, Abeer O. Al-Attar, Mohamad H. Kharita, Antar E. Aly
Journal of Advances in Medicine and Medical Research · pp. 1–7 · Published 24 Mar 2016
10.9734/BJMMR/2016/23975Abstract
The aim of this study was to estimate radiation doses to patients undergoing standard radiographic examinations using Computed Radiography (CR) and Direct Digital Radiography (DDR) in two hospitals within Hamad Medical Corporation (HMC) in Qatar, and compare the results with regional and international Diagnostic Reference Levels (DRLs). Data on 3391 patients were recorded from different X-ray rooms in HMC hospitals. Entrance Skin Dose (ESD) was measured for 1046 patients for the most five common X-ray examinations (a total of 7 projections) namely: Skull, Chest, Abdomen, Lumbar Spine and Pelvis. Exposure factors such as kV, mAs and Focal to Skin Distance (FSD) were recorded for each patient. Tube Output was measured for a range of selected kV values. ESD for each individual patient was calculated using the tube output and the technical exposure factors for each examination. The ESD values were compared with some international DRLs for all types of examinations. HMC patient demographic data evaluated from this study were: average age of 39 years, average weight of 60-80 kg and mean height of 165 cm. The most procedure performed during the time of this study was chest PA (52%), and the least procedure performed was skull AP/LAT (1%) examination. The mean ESD values found to be generally lower than the published values. With exception of abdomen examinations at Hamad General Hospital (HGH), mean ESD values were found to be within the established IAEA (DRL). The mean ESD values at HGH were found to be much higher than that at Al Khor Hospital (AKH) for abdomen, Lumbar spine AP, Lumbar Spine LAT and pelvis, but generally lower than the published values.
Cited by 0
No indexed citations yet.
Related research
- Detecting Dental Caries through Captured Images Using the Machine Learning Technology Teachable Machine — shares topic coverage
- Luminescence of the Conjugate Bases of [2-(2-Hydroxyphenyl)phenyl]phosphinic Acid and Single-Crystal X-Ray Structure Determination of Sodium [2-(2-Hydroxyphenyl)phenyl]phosphinate — shares topic coverage
- Investigation of X-ray Shielding Properties of Concrete Containing Different Percentages of Recycled Lead Shots — shares topic coverage
- Diagnosis of Achilles Tendon Pathology: Ultrasonography Versus Plain X-ray — shares topic coverage
- Synthesis and Crystal Structure of an Air Stable Primary Phosphine-manganese (+1) Complex; fac Tricarbonyl-tris(o-fluorophenylphosphine)-Manganese(+1)-hexafluorophosphate — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.