Measurement of Intraocular Pressure in a Porcine Ex Vivo Model Eye
Irene Sanchez, Raul Martin, Fernando Ussa
Ophthalmology Research: An International Journal · pp. 55–64 · Published 9 Dec 2013
10.9734/OR/2014/6364Abstract
Aims: To compare the pressure inside and outside the pig eye in relation to the location of cannulation for the injection of liquid into the anterior or vitreous chamber. Method: Eleven enucleated pig eyes were used. 46 measurements of intraocular pressure IOP were taken with a Perkins tonometer when the eye was cannulated in the anterior chamber. 49 measurements were taken when the eye was cannulated in the vitreous chamber. The eyeball was connected to a low-pressure transducer to control, maintain and modify the pressure in the eyeball. Results: No significant difference (P=0.138) was found between the Perkins pressure measurements from cannulations in the anterior and vitreous chambers. A linear relationship between transducer and Perkins measurements was found when the eye was cannulated in the anterior chamber (IOP=-7.749+0.763 transducer; R2=0.940, p<0.001) and when it was cannulated in the vitreous chamber (IOP=-7.476+0.730 transducer, R2=0.885, p<0.001). No difference was found between the Perkins/transducer pressure ratios (P=0.500 ANOVA) from cannulations in anterior and vitreous chambers. There were no differences in the measurements among eyes that could affect pressure outcomes. A direct relationship between the insufflate pressure inside the eyeball and the Perkins pressure was found. Conclusion: The pressure measured by Perkins applanation tonometry in an ex vivo porcine eye model is not correlated with the area of cannulation, keeping constant pressure with a low-pressure transducer. A linear equation was generated that correlates the pressure gauge with IOP Perkins, which would apply to future studies that use the pig eye as an exvivo animal model of hypertension in glaucoma.
References (26)
- 1 Global data on visual impairment in the year 2002.
- 2 Lamina Cribrosa and Peripapillary Sclera Histomorphometry in Normal and Advanced Glaucomatous Chinese Eyes with Various Axial Length [DOI]
- 3 Axonal Transport and Cytoskeletal Changes in the Laminar Regions after Elevated Intraocular Pressure [DOI]
- 4 The Relationship between Nerve Fiber Layer and Perimetry Measurements [DOI]
- 5 A population based survey of the prevalence and types of glaucoma in rural West Bengal: the West Bengal Glaucoma Study [DOI]
- 6 Effects of Cholesterol-Lowering Statins on the Aqueous Humor Outflow Pathway [DOI]
- 7 Blebbistatin, a Novel Inhibitor of Myosin II ATPase Activity, Increases Aqueous Humor Outflow Facility in Perfused Enucleated Porcine Eyes [DOI]
- 8 PRIMARY OPEN-ANGLE GLAUCOMA [DOI]
- 9 Keeping an Eye on Myocilin: A Complex Molecule Associated with Primary Open-Angle Glaucoma Susceptibility [DOI]
- 10 Biomechanical Effects of Intraocular Pressure Elevation on Optic Nerve/Lamina Cribrosa before and after Peripapillary Scleral Collagen Cross-Linking [DOI]
- 11 IL-1 and TNF Induction of Matrix Metalloproteinase-3 by c-Jun N-Terminal Kinase in Trabecular Meshwork [DOI]
- 12 Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers [DOI]
- 13 Optimizing the calibration and interpretation of dynamic ocular force measurements [DOI]
- 14 Expression of endothelial leukocyte adhesion molecule 1 in the aqueous outflow pathway of porcine eyes with induced glaucoma.
- 15 Patterns of glaucomatous visual field loss in sita fields automatically identified using independent component analysis.
- 16 Longitudinal glaucoma screening for siblings of patients with primary open angle glaucoma: the Nottingham Family Glaucoma Screening Study [DOI]
- 17 Influence of non-penetrating glaucoma surgery on aqueous outflow facility in isolated porcine eyes [DOI]
- 18 Symmetric sensor for applanation resonance tomometry of the eye [DOI]
- 19 A Modified In Vitro Method for Aqueous Humor Outflow Studies in Enucleated Porcine Eyes [DOI]
- 20 Comparación de tres métodos de inducción del incremento crónico de la presión intraocular en el cerdo (glaucoma experimental) [DOI]
- 21 Acoustic Tonometry [DOI]
- 22 [A new model of induced ocular hyperpressure using the minipig].
- 23 Femtosecond Laser Photodisruption of Porcine Anterior Chamber Angle: An Ex Vivo Study [DOI]
- 24 Prostaglandin F 2 α, but Not Latanoprost, Increases the Ca 2+ Sensitivity of the Pig Iris Sphincter Muscle [DOI]
- 25 [Comparative study of two portable tonometers: Tono-Pen XL and Perkins].
- 26 Cone prism: principles of optical design and linear measurement of the applanation diameter or area of the cornea [DOI]
Cited by 0
No indexed citations yet.
Article metrics
Real usage data collected on this platform.
36
Page views
0
PDF downloads
4
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.