Skip to content
Research Article Open access CC BY 4.0

Quality Assurance in Stereotactic Radiosurgery and Stereotactic Body Radiotherapy

Yucel Saglam, Yasemin Bolukbasi, Ali Ihsan Atasoy, Fatih Karakose, Vildan Alpan, Ugur Selek, Ahmet Kucuk, Berrin Pehlivan, Erkan Topkan

Advances in Research · pp. 22–33 · Published 29 Jun 2020

10.9734/air/2020/v21i730216

Abstract

Stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) have settled down in the center of modern palliative and recently curative intent treatments in the last two decades. Being special, technology-driven, direct knowledge and experience based clinical procedures, both SRS and SBRT require high precision, accuracy and reproducibility to be safely and effectively delivered, which delineates the importance of quality assurance (QA) procedures from head to toe. In this review, we focused on summary of the comprehensive QA program covering clinical, technical and patient-specific treatment aspects, which need to be individualized per department based on several current recommendation guidelines.

Stereotactic radiosurgery stereotactic body radiotherapy stereotactic ablative body radiotherapy quality assurance

Cited by 10

Small field commissioning and verification for the uRT-TPOIS radiotherapy treatment planning system.

Yongguang Liang, Jingru Yang, Lang Yu · Applied Radiation and Isotopes · 2025

Stereotactic radiosurgery in India: A nationwide survey of technology and quality assurance practices.

Parimal T. Patwe, Sudesh S. Deshpande, S. Chaudhari · Journal of Cancer Research and Therapeutics · 2024

Failure modes in stereotactic radiosurgery. A narrative review.

A. Sarchosoglou, P. Papavasileiou, A. Bakas · Radiography · 2022

Patient-Specific QA Using Multidimensional Detectors in Single Isocenter Multitarget Stereotactic Radiotherapy for Multiple Brain Metastasis

M. Ishizawa, Yuya Miyasaka, Hong-Bo Chai · International Journal of Medical Physics Clinical Engineering and Radiation Oncology · 2025

TCRM_A_328375 1053..1064

Y. Saglam, Y. Bolukbasi, A. İ. Atasoy · 2021

A patient-specific QA comparison between 2D and 3D diode arrays for single-lesion SRS and SBRT treatments.

Yongsook C. Lee, Yongbok Kim · Journal of Radiosurgery and SBRT · 2021

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

10

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.