The Critical Decision: Comparing Chest Radiographs at the Bedside and in the Examination Room
Luísa Vargas Cassol, Nataly Nogueira Favarin, Edmeia Lopes Ramai Buss, Miranda Vasconcelos da Silva Claus, Thiago Victorino Claus
Asian Journal of Advanced Research and Reports · pp. 400–405 · Published 1 Aug 2025
10.9734/ajarr/2025/v19i71107Abstract
The transportation of critically ill patients for diagnostic exams requires extreme caution, as it may compromise their clinical stability. To minimize these risks, strict protocols must be followed to ensure patient safety. This study evaluated image quality (IQ) in bedside chest radiographs compared to those performed in the examination room. Ten semi-anatomical phantom images were analyzed while maintaining a constant exposure index. The results indicated that the examinations performed in the examination room increased the contrast (27.19%) (p = 0.003), but also increased the dose at the entrance surface (371.70%) (p < 0.001) due to the use of an anti-scatter grid inherent to the examination room, however, there was a degradation in the average value of the signal-to-noise ratio (SNR) (42%) (p = 0.02). Conversely, bedside images had lower radiation dose and higher SNR but lower contrast. The decision to transport the patient should balance diagnostic accuracy and radiation safety, guided by clinical judgment. Future studies may optimize protocols to enhance IQ while minimizing radiation exposure.
Cited by 0
No indexed citations yet.
Related research
- Effect of Slice Thickness Variation on Spatial Resolution of CT-Scan Device Images at the Bali Mandara Hospital Radiology Installation — shares topic coverage
- Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Effect of Contrast and Brightness on Digital Images under Outdoor Conditions — shares topic coverage
- Image Content Enhancement of Natural Images Using Genetic Algorithm — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.