Skip to content
Research Article Open access CC BY 4.0

Effect of Plastic Strain on Anisotropic Behaviour of AISI202

Vijay Gautam, Prahlad Kumar Tewari, Rohit Shukla

Journal of Scientific Research and Reports · pp. 517–523 · Published 21 Jan 2015

10.9734/JSRR/2015/14466

Abstract

Aims: In the present study an attempt has been made to determine the effect of plastic strain on the anisotropic parameters of AISI202 series. Study Design: The parameter commonly used to characterize the anisotropy of sheet metal is the plastic strain ratio i.e. the ratio of true width-strain to thickness-strain. Accurate determination of plastic strain ratio is difficult as it is influenced by percentage elongation given to the specimen during uniaxial tension test. Moreover, AISI202 shows approximately 60% of uniform strain during tension test and no necking is observed at all, which adds to the problem in accurate determination of anisotropic parameter. Place and Duration of Study: Samples were tested at Plasticity and Metal Forming Laboratory, Department of Mechanical Engineering, Delhi Technological University (DTU), New Delhi, between January 2014 and April 2014. Methodology: Tensile specimens were laser cut from 0.8mm thick sheet in the direction of 0°, 45° and 90° with respect to rolling direction. To determine the effect of percentage elongation, the specimens were tested in tension by giving 15%, 20%, 30% and 35% of plastic strain much before fracture occurs. Results: Experimental results showed that as the plastic strain increased from 15% to a maximum of 35% during tension test, the average plastic strain ratio increased from 0.988 to 1.122 respectively, and the same trend is seen in the values of planar anisotropy which varies between a minimum of 0.025 and maximum of 0.149. The equivalent plastic strain during deep drawing can be as high as 40%; therefore anisotropic behavior at 35% of plastic strain is more accurate and significant to be used in simulations. Conclusion: The experimental studies showed increase in plastic strain ratio on increase in the percentage elongation.

Anisotropy plastic strain rolling direction uniaxial tension test.

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.