Histochemical and Morphological Evaluation of the Conventional Versus Two Rapid Microwave Tissue Processing Techniques
Tobias Peter Pwajok Choji, Peterside Rinle Kumbish, Anthony Ajuluchukwu Ngokere, Samuel Ifedioranma Ogenyi, James O. Adisa, Boniface Nnamdi Duru, Comfort Danchal, Linus Doro Danjuma, Kaneng Pam Sha, Rifkatu Davou Pam
Archives of Current Research International · pp. 77–95 · Published 20 Oct 2015
10.9734/ACRI/2015/20765Abstract
Aims: To utilize the laboratory microwave as a processing instrument in place of the automatic tissue processor, to replace xylene with isopropanol in the clearing stage of tissue processing and check its effect on the chemical reactivity and tissue integrity, to establish a rapid method of tissue processing. Study Design: Fixation and grossing of tissues into triplicates. Processing, sectioning and histochemical demonstration of cells and extracellular components. Scoring of blocks and section, statistical evaluation of grades. Place and Duration of Study: The study was carried out at the central diagnostic Division, National Veterinary Research Institute, Vom, Jos, Nigeria, for 8 months between October, 2014 and May, 2015. Methodology: The Trachea, Lungs, Heart, Liver, Kidney, Stomach, Skin, Brain, and the Spleen were harvested from each of two apparently healthy rabbits after scientific ally sacrificing them and fixed in 10% buffered formalin for 3 days. They were grossed into triplicates, labeled and processed using the conventional, microwave without vacuum and microwave with vacuum respectively. They were sectioned and subjected to some histochemical methods as well as silver impregnation, graded and average scores subjected to one way Analysis of Variance (ANOVA) at 95% confidence interval. P-values less than 0.05 were considered statistically significant. Results: Reagents and time consumption were severely reduced in the microwave techniques when compared with the conventional method even as xylene was replaced with isopropanol, a cheaper and more user-friendly reagent than xylene. There was no statistically significant difference among the three techniques in terms of section preparation (P=.22), details of microscopic assessment/quality of tissue preservation (P=.74) and details of microscopic assessment/quality of staining (P=.90). Microscopic assessment/physical quality is also comparable among the three techniques (P=.74). Conclusion: A cheaper and faster method of tissue processing as presented in this work shows that histology results can be results in less than three hours of sample arrival. Xylene, with its deleterious effects on both the tissue and the laboratory personnel can now be eliminated from the processing schedule, with no negative effects of tissue morphology nor dye uptake. This was will encourage speed and accuracy in histopathology thereby improving patient care and management. Tissues processed using the microwave techniques can be assessed immunohistochemically since the microwave itself is used for antigen retrieval.
References (15)
- 1 Oral and Maxillofacial Pathology: A Rationale for Diagnosis and Treatment
- 2 RCL2, a New Fixative, Preserves Morphology and Nucleic Acid Integrity in Paraffin-Embedded Breast Carcinoma and Microdissected Breast Tumor Cells [DOI]
- 3 Oral biopsies: methods and applications [DOI]
- 4 The role of apoptosis in the development of renal cortical tubular atrophy associated with healed experimental renal papillary necrosis [DOI]
- 5 The Effects of Tissue Processing Variables Other Than Fixation on Histochemical Staining and Immunohistochemical Detection of Antigens [DOI]
- 6 A Comparison of Immunohistochemical Stain Quality in Conventional and Rapid Microwave Processed Tissues [DOI]
- 7 Evaluation of Ethanol-based Fixatives as a Substitute for Formalin in Diagnostic Clinical Laboratories [DOI]
- 8 Microwave histoprocessing versus conventional histoprocessing [DOI]
- 9 Cost Effective, Environmentally Safe Tissue Processing Method With Paraffin Oil [DOI]
- 10 Staining reactions of microwave processed tissues compared with conventional paraffin wax processed tissues
- 11 Ultra-Rapid Microwave/Variable Pressure-Induced Histoprocessing: Description of a New Tissue Processor [DOI]
- 12 Histo-architechtural Evaluation of Conventional Versus Two Rapid Microwave Processing Techniques [DOI]
- 13 A Study on Tissue Processing
- 14 Domestic Microwave Versus Conventional Tissue Processing: A Quantitative and Qualitative Analysis [DOI]
- 15 The two-step vacuum-microwave method for histoprocessing.
Cited by 1
Pranav Naresh Shirbhate, Abhay Vilas Deshmukh, Vitaladevuni Balasubramanyam Shivkumar · Medical Journal of Babylon · 2022
Related research
- Immunohistochemical Expression of Epstein-Bar Virus in Biopsies Bearing Oral Squamous Cell Carcinoma — shares topic coverage
- Mantle Cell Lymphoma of Gastrointestinal Tract as a Lead Point for Intussusception: A Case Report — shares topic coverage
- Neoplasias in Fish: Review of the Last 20 Years. A Look from the Pathology — shares topic coverage
- Ameliorative Properties of the Chloroform Stem Bark Extract of Abrus precatorius against Gentamicin-induced Renal Damage in Rats — shares topic coverage
- Enalapril Confers Protective Effect on Isoproterenol-Induced Myocardial Infarction in Rats through Downregulation of Cardiac Troponin, C-reactive Protein, Upregulation of IL-10β as Well as Anti-Oxidant and Anti-inflammatory Activities — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.