Skip to content
Research Article Open access CC BY 4.0

Frequency of Atrial Fibrillation after Coronary Artery Bypass Grafting in an Asian Tertiary Care Hospital

Ibrar Ahmad Khan, Awais Kazim, Badr Mansoor, Wardah Malik

Asian Journal of Cardiology Research · pp. 162–169 · Published 18 Jun 2021

Abstract

Introduction: Post-surgical atrial fibrillation is a common arrhythmic complication of coronary artery bypass surgery. However, mostly it is thought to be a benign and self-limiting problem, but it has also been observed that it is a serious complication and can raise the number of complications after bypass surgery. Aims: To assess the frequency of atrial fibrillation after coronary artery bypass grafting Study Design: Cross-sectional study Place and Duration of Study: Department of Cardiology, Punjab Institute of Cardiology (PIC), Lahore, between February 2018 and August 2018. Methodology: 145 patients who fulfilled the selection criteria were enrolled in the study. The type of CABG (on-pump or off-pump) was noted from the medical record. Then patients were evaluated by an ECG monitor. If P waves were absent, with disorganized electrical activity in their place, and irregular R-R intervals due to irregular conduction of impulses to the ventricles and heart rate>100bpm, then atrial fibrillation was labeled. Results: The mean age of patients was 53.08±8.80 years. There were 84(57.9%) males and 61(42.1%) were females. There were 61(42.1%) patients with 2 vessels involved while among 84(57.9%) patients triple vessels were involved. There were 86(59.3%) with On-pump CABG and 59(40.7%) with off-Pump CABG. There were 71(49%) patients with follow-up atrial fibrillation and 74(51%) have no followed up atrial fibrillation. There was no significant association between atrial fibrillation and age group as the p-value was not significant. Conclusion: CABG is associated with a higher frequency of atrial fibrillation after CABG as in our study the frequency was 49%.

Atrial fibrillation coronary artery bypass grafting surgical procedure on-pump off-pump

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.