Skip to content
Research Article Open access CC BY 4.0

Optimization of Antigen Concentrations to Improve the Signal-to-Noise Ratio of ELISA Tests for the Detection of Anti-Plasmodium falciparum Antibodies

Nicolas Ouédraogo, Fatimata Thiombiano, Oumarou OUEDRAOGO, Mireille OUEDRAOGO, Guillaume Sylvestre SANOU, Harouna SORE, Casimire Wendlamita TARAMA, François Tapsoba, Yéri Esther HIEN, Kaba Mariama CHERIF, Aly Savadogo

Journal of Advances in Microbiology · pp. 79–90 · Published 19 Feb 2026

10.9734/jamb/2026/v26i21075

Abstract

Malaria, caused by the parasite Plasmodium falciparum, remains a major public health priority in tropical regions. The Enzyme-Linked Immunosorbent Assay (ELISA) for detecting anti-Plasmodium antibodies is an essential diagnostic tool. However, its sensitivity and specificity are closely dependent on the concentration of antigens used. This study aimed to determine the optimal antigen concentration for seven P. falciparum antigens (AMA1, MSP1, GLURP, CSP, EBA175, MSP3, and EXP1) in order to optimize the signal-to-background noise ratio of indirect ELISA tests. To achieve this, titration microplates were coated with serial dilutions of each antigen (from 2 µg/ml to 0.0625 µg/ml), incubated with patient sera, and then developed using conjugated secondary antibodies. Each antigen concentration was tested in duplicate wells (n=2), using Hyper-Immune Tanzanian (HIT) plasma at antigen-specific dilutions (e.g., 1:200 for CSP/MSP1, 1: 10,000 for EXP1), alongside positive and negative controls. Optimal concentrations were identified by plotting titration curves of optical density (OD450) versus antigen dilution and selecting the point maximizing the signal-to-noise ratio (positive minus negative control OD). Reproducibility was ensured by calculating the coefficient of variation (CV) between duplicates, repeating tests if CV >15%. The optimal antigen concentrations identified for improved diagnostic performance were as follows: AMA1 (1 µg/ml), MSP1 (0.18 µg/ml), GLURP (0.5 µg/ml), CSP (0.25 µg/ml), EXP1 (0.25 µg/ml), EBA175 (2 µg/ml), and MSP3 (0.5 µg/ml). These results may support the standardization of malaria diagnostic protocols and enhance the performance of serological tests.

Titration antigens ELISA Plasmodium falciparum optimization antigen concentration

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.