Optimization of Antigen Concentrations to Improve the Signal-to-Noise Ratio of ELISA Tests for the Detection of Anti-Plasmodium falciparum Antibodies
Nicolas Ouédraogo, Fatimata Thiombiano, Oumarou OUEDRAOGO, Mireille OUEDRAOGO, Guillaume Sylvestre SANOU, Harouna SORE, Casimire Wendlamita TARAMA, François Tapsoba, Yéri Esther HIEN, Kaba Mariama CHERIF, Aly Savadogo
Journal of Advances in Microbiology · pp. 79–90 · Published 19 Feb 2026
10.9734/jamb/2026/v26i21075Abstract
Malaria, caused by the parasite Plasmodium falciparum, remains a major public health priority in tropical regions. The Enzyme-Linked Immunosorbent Assay (ELISA) for detecting anti-Plasmodium antibodies is an essential diagnostic tool. However, its sensitivity and specificity are closely dependent on the concentration of antigens used. This study aimed to determine the optimal antigen concentration for seven P. falciparum antigens (AMA1, MSP1, GLURP, CSP, EBA175, MSP3, and EXP1) in order to optimize the signal-to-background noise ratio of indirect ELISA tests. To achieve this, titration microplates were coated with serial dilutions of each antigen (from 2 µg/ml to 0.0625 µg/ml), incubated with patient sera, and then developed using conjugated secondary antibodies. Each antigen concentration was tested in duplicate wells (n=2), using Hyper-Immune Tanzanian (HIT) plasma at antigen-specific dilutions (e.g., 1:200 for CSP/MSP1, 1: 10,000 for EXP1), alongside positive and negative controls. Optimal concentrations were identified by plotting titration curves of optical density (OD450) versus antigen dilution and selecting the point maximizing the signal-to-noise ratio (positive minus negative control OD). Reproducibility was ensured by calculating the coefficient of variation (CV) between duplicates, repeating tests if CV >15%. The optimal antigen concentrations identified for improved diagnostic performance were as follows: AMA1 (1 µg/ml), MSP1 (0.18 µg/ml), GLURP (0.5 µg/ml), CSP (0.25 µg/ml), EXP1 (0.25 µg/ml), EBA175 (2 µg/ml), and MSP3 (0.5 µg/ml). These results may support the standardization of malaria diagnostic protocols and enhance the performance of serological tests.
Cited by 0
No indexed citations yet.
Related research
- Seroprevalence and Risk of Primary Maternal HCMV Infection among Pregnant Women in Taiz City, Yemen — shares topic coverage
- Serological and Immunohistochemical Prevalence of Human Cytomegalovirus Co-infection among Hepatitis C Virus Patients Admitted to Kafer El Shiekh Liver and Heart Institute, Egypt — shares topic coverage
- Prevalence of Occult Hepatitis B Virus Infection among Healthy Hbsag Negative Blood Donors in Owerri Town, South-east Nigeria — shares topic coverage
- Detection of Dengue Virus in Samples from Suspected Yellow Fever Cases in Ghana — shares topic coverage
- Sero Prevalence of Equine Infectious Anemia (EIA) Virus in Selected Regions in Sudan — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.