Skip to content
Research Article Open access CC BY 4.0

Optimization of Steam Boiler Airflow Control System in a Typical Oil Refinery Power Plant

Ejimaji, Ambrose Obutor, Chukwunazo J. Ezeofor

Journal of Engineering Research and Reports · pp. 100–113 · Published 29 Oct 2024

10.9734/jerr/2024/v26i111317

Abstract

This paper presents optimization of Steam Boiler Airflow Control System in a Typical Oil Refinery Power Plant. The power plant is equipped with four steam boilers using a damper-louvers airflow control system. Analysis has revealed significant energy wastage due to inefficiency and over-air supply, with the system requiring 59,904,436 kWh annually at a financial cost of N1, 093,255,884. The existing system's inefficiency results in an annual electrical energy waste of 8,502,302 kWh. This inefficiency is attributed to the Force Draft Fan (FDF) motor operating at maximum speed continuously, regardless of the steam profile or airflow requirements. This study aimed at optimizing the steam boiler airflow control system in a typical oil refinery power plant for improved power efficiency, energy conservation, and cost savings citing Port Harcourt Refinery Company (PHRC) at Alesa-Eleme, Rivers State, Nigeria. To address this, the damper-louvers system was replaced with a Variable Frequency Drive (VFD), which would adjust the motor speed to match the required airflow, thereby reducing energy wastage. The process was simulated and VFD/FDF motor analyzed in MATLAB Simulink, determining the optimal speed, airflow, and power requirements. Results obtained show that the VFD control system improves the FDF motor's power efficiency from 47.7% to 85%, with an annual energy saving of 8,502,302 kWh (8.5 GWh). This results in a total cost benefit of N478.18 million annually, representing a 43.8% cost saving. The implementation cost of the VFD infrastructure was estimated at N111, 440,000, with a payback period of approximately eleven months. The findings suggest deployment of higher FDF motor speed ratings to enhance speed control and energy efficiency in Oil refinery power plant.

Force draft fan variable frequency drive airflow control system MATLAB Simulink energy conservation cost saving opportunity PHRC

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.