Skip to content
Research Article Open access CC BY 4.0

Ozonated Water Decreases In vitro Contamination at Dental Implant Interface in Different Connections

Eder José Cruz, Renato Bitencourt Rosado, Lucas Trevisan Suzzin, Karina Maria Salvatore Freitas, Ana Paula Uber, Mariana Aparecida Lopes Ortiz, Samira Salmeron

Journal of Advances in Medicine and Medical Research · pp. 272–279 · Published 13 Aug 2024

10.9734/jammr/2024/v36i85546

Abstract

Aim: Cases of peri-implant diseases have increased, highlighting the need for preventive and therapeutic protocols. This study aimed to evaluate the effectiveness of ozonated water on In vitro decontamination of implant-abutment interfaces in external hexagon (EH) and morse cone (MC) connections. Study Design: In vitro study. Place and Duration of Study: Sample: Department of Periodontics and Implant Dentistry of Ingá University Center – UNINGÁ, between June 2020 and December 2021. Methodology: Twenty-four implant-abutments (IA) in EH (n=12) and MC (n=12) connections were divided into groups: negative control (NC) – sterile IA; positive control (PC) – IA contaminated with biofilm; and ozone (O) – IA contaminated with biofilm and decontaminated with ozonated water (60µg/mL,1min). The effectiveness of ozonated water was evaluated by counting colony-forming units (CFU/mL), and both connection types were compared. Results: There was a significant difference among groups in both connection types, outside and inside the implants (P=0.000). Group O showed a significant decrease in CFU/mL compared to group PC outside and inside the implants for EH and MC connections (P=0.000). Only group O in the EH connection presented a significative difference in CFU/mL compared to outside and inside the implants (2.475x103±0.320 and 1.775x103±0.125, respectively) (P=0.033). Comparison between connections was statistically different for groups PC and O, outside and inside the implants (P=0.000). Conclusion: Ozonated water showed effectiveness in vitro decontamination of implant-abutment interfaces in both connection types.

Dental implant-abutment interface ozone decontamination biofilm

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.